Technical data

March 2009
33-70
For more information visit: www.eaton.com CA08102001E
NEMA Contactors & Starters
33
Freedom
Contactors — Non-reversing and Reversing
Contents
Description Page
Product Family Overview
Product Description. . . . . . . 33-68
Features . . . . . . . . . . . . . . . . 33-68
Standards and
Certifications . . . . . . . . . . . 33-68
Catalog Number
Selection . . . . . . . . . . . . . . 33-69
Contactors — Non-reversing
and Reversing
Product Description. . . . . . . 33-70
Features . . . . . . . . . . . . . . . . 33-70
Technical Data . . . . . . . . . . . 33-70
Product Selection —
3-Pole Contactors . . . . . . . 33-71
Product Selection —
2-, 4- and 5-Pole
Contactors . . . . . . . . . . . . . 33-72
Technical Data. . . . . . . . . . . . . . 33-79
Accessories . . . . . . . . . . . . . . . . 33-82
Auxiliary Contacts . . . . . . . . 33-86
DC Magnet Coils . . . . . . . . . 33-88
Mounting Plates. . . . . . . . . . 33-89
Special Modifications. . . . . . . . 33-90
Renewal Parts . . . . . . . . . . . . . 33-91
Dimensions . . . . . . . . . . . . . . . . 33-94
Product Description
Non-reversing
Contactors are most commonly used
to switch motor loads in applications
where running overcurrent protection
is either not required or is provided
separately. Contactors consist of a
magnetically actuated switch which
can be remotely operated by a push-
button station or pilot device such as
a proximity switch, limit switch, float
switch, auxiliary contacts, etc.
Reversing
Reversing contactors are used prima-
rily for reversing single- or three-phase
motors in applications where running
overcurrent protection is either not
required or is provided separately.
They consist of two contactors
mechanically and electrically inter-
locked to prevent line shorts and
energization of both contactors
simultaneously.
Features
Designed specifically for use in
applications requiring NEMA rat-
ings. Contactors meet or exceed
NEMA standards ICS 2-1993.
Long life twin break, silver cadmium
oxide contacts — provide excellent
conductivity and superior resistance
to welding and arc erosion.
Designed to 3,000,000 electrical
operations at maximum hp ratings
up through 25 hp at 600V.
Steel mounting plate standard on all
open type contactors.
Non-reversing
Holding circuit contact(s) supplied
as standard:
Sizes 00 – 3 have NO auxiliary
contact block mounted on right
hand side (on Size 00, contact
occupies 4th power pole position
— no increase in width).
Sizes 4 – 5 have a NO contact
block mounted on left side.
Sizes 6 – 7 have a 2NO/2NC
contact block on top left.
Size 8 has a NO/NC contact block
on top left back and a NO contact
block on top right back.
Reversing
One NO-NC side mounted interlock
supplied as standard on each con-
tactor for Sizes 00 – 8.
Technical Data
Table 33-90. Wire (75°C) Sizes — AWG or
kcmil — Open and Enclosed
Two compartment box lug.
Table 33-91. Plugging and Jogging Service
Horsepower Ratings
Maximum horsepower where operation is
interrupted more than 5 times per minute or
more than 10 times in a 10 minute period.
NEMA standard ICS 2-1993 table 2-4-3.
Kits and Accessories
Auxiliary Contacts, contactor
mounted — Pages 33-86 and 33-87.
Transient Suppressor, for magnet
coil — Pages 33-84.
Timers — Solid-State and
Pneumatic, mount on contactor —
Page 33-83.
Renewal Parts Publication
Numbers
See Page 33-91.
NEMA Size 1 — Cat. No. CN15DN3AB
NEMA Size 1
Cat. No. CN55DN3AB
NEMA
Size
Power Terminals
Line or Load
Control
Terminals
Cu Only
00 12 – 16 stranded;
12 – 14 solid Cu
12 – 16
stranded
12 – 14
solid
08 – 16 stranded;
10 – 14 solid Cu
18 – 14 stranded or
solid Cu
23 – 14 (upper) and/or
6 – 14 (lower) stranded
or solid
Cu
3 1/0 – 14 Cu/Al
4 250 mcm – 6
5 750 kcmil – 2, or
(2) 250 kcmil – 3/0 Cu/Al
6 (2) 750 kcmil – 3/0 Cu/Al
7 (3) 750 kcmil – 3/0 Cu/Al
8 (4) 750 kcmil – 4/0 Cu/Al
NEMA
Size
200V 230V 460V 575V
00
0
1
2
3
4
5
6
1-1/2
3
7-1/2
15
25
60
125
1/2
1-1/2
3
10
20
30
75
150
1/2
2
5
15
30
60
150
300
1/2
2
5
15
30
60
150
300