Technical data

March 2009
CA08102001E For more information visit: www.eaton.com
33-7
NEMA Contactors & Starters
33
IT. Electro-Mechanical
Starters — Full Voltage, Non-reversing and Reversing
Contents
Description Page
Product Family Overview
Product Description . . . . . . 33-2
Standards and
Certifications . . . . . . . . . . 33-2
Catalog Number
Selection . . . . . . . . . . . . . 33-3
Starters — Non-reversing
and Reversing
Product Description . . . . . . 33-7
Features . . . . . . . . . . . . . . . 33-7
Product Selection. . . . . . . . 33-8
Technical Data and
Specifications . . . . . . . . . . . . 33-10
Accessories . . . . . . . . . . . . . . . 33-13
Auxiliary Contacts . . . . . . . 33-15
Renewal Parts . . . . . . . . . . . . . 33-17
Dimensions . . . . . . . . . . . . . . . 33-22
Product Description
The Cutler-Hammer
®
Intelligent
Technologies (IT.) Electro-Mechanical
Starter from Eaton’s electrical business
consists of an IT. Electro-Mechanical
Contact Block or Contactor and IT.
Electro-Mechanical Solid-State
Overload Relay as a Full Voltage
Non-reversing (FVNR) or Full Voltage
Reversing (FVR) device. Size 00 to Size 5
Starters are factory or field assembled.
Features
24V DC control power — safe, reliable
global standard
Unique Pulse Width Modulated
(PWM) coil controller minimizes coil
power consumption
Microprocessor based control
Phase loss and current unbalance
protection, user selectable
Standard selectable Trip Class 10, 20
(factory default) or 30 — no individ-
ual part numbers — no program-
ming software
Ambient compensated overload
Motor temperature and power-up
protection with thermal memory
Front and side mounted Auxiliary
Contacts: 1NO, 1NC, 2NO, 2NC,
1NO/1NC and logic level (1NO/1NC)
Easily accessible mounting feet for
panel mounting
LED status indication — trip, trip
class, motor thermal state, reset,
overload state
Unique “Alarm without Trip” option
for critical must run applications
Lockable overload cover protects
against unauthorized adjustment
and reset functions
No control wiring needed between
contactor and overload relay —
eliminates seal in auxiliary contacts
Minimal heat — no full voltage coils
-40° to 149°F (-40° – 65°C) operating
temperature
Wide 3.2:1 current adjustment range
Exclusive internal 24-bit floating
point math calculations with RMS
calibrated current measurement
Meets or exceeds global standards
for EMC (Electromagnetic compati-
bility) immunity and emissions
IP20 Finger Protection
Motor running thermal utilization
indication
Manual, Automatic or Remote Reset
Easy field assembly of control
wiring — plug and unplug lockable
control connector
DIN rail mountable, Size 00 – 2
Communication Interface with
Starter Network Adapter Product
(SNAP)
2- or 3-wire control
Solid-state alarm output indication
Optional mounting plates with
“Ease of Installation” slotted hole
design
Type 2 Coordination
Conformal coated printed circuit
boards for resistance to harsh
environments
Reversing Starters
Includes Reversing Power Wiring
and bus bars
Mounting plates for Size 00 – 4
Built-in electronic interlock for FVR
units
Unique overload board energizes
both forward and reverse starters —
one control point for wiring
NEMA Full Voltage
Non-reversing Starter, Size 0
NEMA Full Voltage Reversing
Starter, Size 0