Technical data

March 2009
33-228
For more information visit: www.eaton.com CA08102001E
NEMA Contactors & Starters
33
Advantage, Full Voltage — Enclosed
Wiring Diagrams
Wiring Diagrams
Figure 33-86. Advantage Non-reversing — Non-combination
Figure 33-87. Advantage Non-reversing — Combination
1
Remote Control
120V AC 50/60 Hz
1
X2
Stop
Start
3
2
3-Wire Control
with Internal Holding
Circuit Interlock
Optional
(Optional)
Emergency Stop
M
M
R
G
Run
OFF
1
OFF
Hand Auto
Start
4
3
3A
XOO
OXX
M
Jumper
Optional
Emergency Stop
Optional
Emergency Stop
Remote Control
X2
2-Wire Control
with HOA Switch
and START Button with
External Holding Circuit
X2
2-Wire Control
with HOA
1
OFF
Hand Auto
XOO
OOX
3A
3
Jumper
Start
3-Wire Control
Not for Use with Auto
Reset Overload Relays.
Elementary Diagram Remote Pilot Devices
Figure A
Figure B
Figure C
AC Lines
Solid-State
Overload Relay
L1
L2
L3
M
T1
Motor
T2
T3
3
Start
P
Run Permit
M
Stop
Top
E
Power
C
Common
3
Start
P
Run Permit
M
Stop
Top
E
Power
C
Common
3
Start
P
Run Permit
M
Stop
Top
E
Power
C
Common
3
P
1
Start
Stop
2-Wire Control
3
P
Hand Auto
OFF
Figure C
13
3A
A
B
X = Closed
A
B
Contact
Position
Hand OFF
X
Auto
XX
X = Closed
A
B
Contact
Position
Hand OFF
X
Auto
X
1
1H3
H4
Fuse
Fuse
Fuse
H1
H2 4
X2
X2
XF
X1
CPT
C
Secondary
Connections
Primary
Connections
L2
L1
G
Figure 1
Connections for Dual Voltage Rated
Transformer – See Transformer Nameplate
260955 D3
Control Circuit Transformer (If Used)
Hand Auto
OFF
Figure B
Figure A
1
3A
4
3
A
B
120V AC 50/60 Hz
1
Add Jumper 3 to P
2-Wire Control
Remote Control
Not for Use with Auto
Reset OL Relays.
3-Wire Control
Start
Stop
3
2
1
When More Than One
Pushbutton Station Is Used,
Omit Connector “A” and
Connect per Sketch at Right.
3
2
1
“A”
Start
Start
Stop Stop
Combined Remote and Local
For Figures 1 and 2
Remote
Local
Start (ON)
2
3
1
Start
Stop
Stop (OFF)
3
4
2
1
Figure A
START/STOP Pushbuttons
Figure D
2-Position Selector Switch
3
2
1
Stop (OFF)
Start (ON)
3
4
2
1
Omit
Connector
Figure 1
Front View Diagram
Figure 2
Fusible Control Transformer
M
Reset
T1
T2
T3
T1
T2
Motor
T3
T2T1 T3
Reset
Local
Control
(Flange
Mounting
If Used)
See
Figures
A to E
Elementary Diagram
Start
Stop
11
3
2
2A
R
G
Run
Stopped
Reset
6
M
5
7
M
8
Connections for Control Stations Connections for Starters
Solid-State
Overload
Protection
M
T1
Motor
T2
T3
3
Start
P
Run Permit
M
Stop
Top
E
Power
C
Common
260962 D4
H4
4
H2
H3
1
H1
X1
XF
X2
Fuse
Fuse
Fuse
CPT
1
Secondary
Connections
Primary Connections
L1 L2
G
M X2(C)
Connections for Dual Voltage Rated Transformer –
See Transformer Nameplate
Circuit
Breaker
or Switch
and Fuse
(If Used)
L3
L2
L2
L1
L1
1
2
3
Full Voltage
Non-reversing
CPT
Fusible
Control
Transformer
(If Used)
See Figure 2
D.S. or C.B.
Disconnecting
Means
(If Used)
L3
3
L1 L2
L3L1 L2
21
1
2
3
321
Solid-State
OL Protection
3P
2
E
1
C
X2
Pilot Light (Motor RUN)
Black/White
Black/White
X1
X2
Connect to
Terminals
”6“ and ”X2“
4
4
3
3
Hand
2(P)
Auto
1
3
3
3
2
4
3
1
Hand
2(P)
Auto
1
START/STOP Selector Switch
2
4
3
1
Start
(ON)
1
Local Control
Figure E
3-Position Selector Switch
Figure C
Figure B