Technical data

March 2009
33-222
For more information visit: www.eaton.com CA08102001E
NEMA Contactors & Starters
33
Advantage, Full Voltage — Enclosed
Product Family Overview
Catalog Number Selection
Table 33-337. Advantage Line Enclosed Control Catalog Numbering System
Contact Eaton for more information.
Use with Sizes L – 3, HMCP 600V applications only.
Table 33-338. Magnet Coil Codes (System Voltage)
When control power transformer modification codes (C1C11) are
used or when starter class includes CPT (i.e. ECN07, 18), see Table 33-339
for system voltage code.
Table 33-339. Control Power Transformer Codes (System Voltage)
E C A 2 2 2 1 A A F -
Design
A = Advantage NEMA
Class Table
01 =
02 =
05 =
06 =
07 =
16 =
17 =
18 =
22 =
23 =
24 =
33 =
34 =
35 =
36 =
37 =
38 =
39 =
40 =
41 =
42 =
43 =
44 =
45 =
46 =
47 =
48 =
49 =
50 =
51 =
52 =
53 =
54 =
55 =
62 =
63 =
64 =
65 =
68 =
69 =
70 =
Contactors
Reversing Contactors
Non-combination Non-reversing Starter
Non-combination Reversing Starter
Non-combination Non-reversing Starter, with CPT
Combination Non-reversing Starter —
Fusible Disconnect
Combination Reversing Starter
with Disconnect Switch
Combination Reversing Starter — Fusible/
Non-fusible Disconnect with CPT
Combination Non-reversing Starter —
Circuit Breaker
Reversing, Combination with HMCP/E
Combination with HMCP/E with CPT
Multispeed 2S2W Non-combination
Multispeed 2S1W CT or VT Non-combination
Multispeed 2S1W CH Non-combination
Multispeed with Disconnect Switch, 2S2W
Multispeed with Disconnect Switch, 2S1W CT or VT
Multispeed with Disconnect Switch, 2S1W CH
Multispeed with HMCP/E, 2S2W
Multispeed with HMCP/E, 2S1W CT or VT
Multispeed with HMCP/E, 2S1W CH
Autotransformer, Non-combination
Autotransformer, with Disconnect Switch
Autotransformer, with HMCP/E
Part-Winding, Non-combination
Part-Winding, with Disconnect Switch
Part-Winding, with HMCP/E
Y-D, Open Transition, Non-combination
Y-D, Open Transition, with Disconnect Switch
Y-D, Open Transition, with HMCP/E
Y-D, Closed Transition, Non-combination
Y-D, Closed Transition, with Disconnect Switch
Y-D, Closed Transition, with HMCP/E
Std Width Pump Panel, with Disconnect Switch
Std Width Pump Panel, with HMCP/E
Autotransformer Pump Panel, Disconnect Switch
Autotransformer Pump Panel, HMCP/E
Part-Winding Pump Panel, Disconnect
Part-Winding Pump Panel, Circuit Breaker
Duplex, Non-combination
Duplex, with Disconnect Switch
Duplex, with HMCP/E
33-341
33-342
33-343
33-344
NEMA Size
L =
1 =
2 =
3 =
Lower 1
Size 1
Size 2
Size 3
4 =
5 =
6 =
Size 4
Size 5
Size 6
Modification Codes
See Page 33-42
Coil Voltage and/or Control Transformers
See Tables 33-338 and 33-339
Disconnect Fuse Clip Ratings
A =
B =
C =
D =
E =
F =
None
30A/250V R
30A/600V R
60A/250V R
60A/600V R
100A/250V R
G =
H =
J =
K =
L =
M =
100A/600V R
200A/250V R
200A/600V R
400A/250V R
400A/600V R
600A/250V R
N =
P =
Q =
R =
S =
T =
600A/600V R
800A/600V R
1200A/600V R
1600A/600V R
2000A/600V R
by Description
HMCP/E or Breaker Ratings
A =
B =
C =
D =
E =
F =
W =
G =
None
3A
7A
15A
30A
50A
70A
100A
H =
J =
K =
L =
M =
N =
P =
Q =
150A
250A
400A
600A
800A
1000A
1200A
2000A
R =
T =
5 =
6 =
7 =
8 =
9 =
I =
3000A
by Description
3A
7A
15A
30A
50A
100A
Enclosure Type
1 =
2 =
3 =
4 =
5 =
6 =
7 =
8 =
9 =
Type 1 — General Purpose
Type 3R — Rainproof
Type 4 — Watertight (Painted Steel)
Type 4X — Watertight (304-Grade Stainless Steel)
Type 4X — Corrosion (Nonmetallic)
Type 7/9 — Bolted Hazardous Location
Type 7/9 — Threaded Hazardous Location
Type 12 — Dust-Tight
Type 4X — 316-Grade Stainless Steel
Cover Control — Starters
10250T and E22 style, see Tables 33-186 –
33-188
Flange-Mounted ACM, see Table 33-340
Contactors
3 = 3 Poles
Code Magnet Coil Code Magnet Coil
F
N
120/60
110/50
Z By Description
Code Primary Secondary Code Primary Secondary
B
C
D
E
240/480 – 220/440
Wired for 240V
240/480 – 220/440
Wired for 480V
600/60 – 550/50
208/60
120/60 – 110/50
120/60 – 110/50
120/60 – 110/50
120/60
H
L
M
X
Z
277/60
380/50
415/50
240/480/600
Wired for 480V
By Description
120/60
110/50
110/50
120