Technical data

March 2009
33-186
For more information visit: www.eaton.com CA08102001E
NEMA Contactors & Starters
33
A200 — Enclosed Control
Combination Starters — Fusible and Non-fusible
Table 33-287. Class EC216 — Combination Non-reversing Starter — Fusible Disconnect (Continued)
For Ambient Compensated Overload Relay with Auto-Reset, add suffix D.
The Catalog Numbers listed in the Type 4X column are for Type 4X 304-Grade Stainless Steel, as indicated by the seventh digit 4.
Example: EC21604
EAB. To order Type 4X 316-Grade Stainless Steel, change that digit to 9. To order Type 4 Painted Steel, change that digit to 3.
To order Nonmetallic, change that digit to 5. For details on these Alternate Enclosures, see PG03300001E.
All Type 12 enclosures are standardized with external reset. For internal reset, order Mod Code R5.
Type 12 enclosure is without safety door interlock. When safety door interlock is required, add modification E11.
Contact Eaton.
Type 4 (Painted steel) Sizes 6 – 9.
NEMA
Size
Motor
Voltage
Max. hp
Rating
Dual
Element
Fuses
Magnet
Coil
Voltage
Fuse
Clip
Amps
Type 1
General Purpose
Type 3R
Rainproof
Type 4X
Watertight &
Dust-Tight
Stainless Steel
Type 12
Dust-Tight Industrial
External Reset

Component
Starter
(Open)
Catalog
Number
Catalog
Number
Catalog
Number
Catalog
Number
Catalog
Number
5—
200
230
460
575
75
100
200
200
120
208
240
480
600
400A
EC21651AAK
EC21651EAK
EC21651BAK
EC21651CAL
EC21651DAL
EC21652AAK
EC21652EAK
EC21652BAK
EC21652CAL
EC21652DAL
EC21654AAK
EC21654EAK
EC21654BAK
EC21654CAL
EC21654DAL
EC21658AAK
EC21658EAK
EC21658BAK
EC21658CAL
EC21658DAL
A200M5CAC
A200M5CB
A200M5CW
A200M5CX
A200M5CE
6—
200
230
460
575
150
200
400
400
120
208
240
480
600
600A
EC21661AAM
EC21661EAM
EC21661BAM
EC21661CAN
EC21661DAN
EC21662AAM
EC21662EAM
EC21662BAM
EC21662CAN
EC21662DAN
EC21663AAM
EC21663EAM
EC21663BAM
EC21663CAN
EC21663DAN
EC21668AAM
EC21668EAM
EC21668BAM
EC21668CAN
EC21668DAN
A200M6CAC
A200M6CB
A200M6CW
A200M6CX
A200M6CE
7—
230
460
575
300
600
600
120
240
480
600
EC21671AAU
EC21671BAU
EC21671CAU
EC21671DAU
EC21672AAU
EC21672BAU
EC21672CAU
EC21672DAU
EC21673AAU
EC21673BAU
EC21673CAU
EC21673DAU
EC21678AAU
EC21678BAU
EC21678CAU
EC21678DAU
A200M7CJ
A200M7CW
A200M7CX
A200M7CE
8—
230
460
575
450
900
900
120
240
480
600
EC21681AAU
EC21681BAU
EC21681CAU
EC21681DAU
EC21682AAU
EC21682BAU
EC21682CAU
EC21682DAU
EC21683AAU
EC21683BAU
EC21683CAU
EC21683DAU
EC21688AAU
EC21688BAU
EC21688CAU
EC21688DAU
A200M8CJ
A200M8CW
A200M8CX
A200M8CE
9—
230
460
575
800
1000
1000
120
240
480
600
EC21691AAU
EC21691BAU
EC21691CAU
EC21691DAU
EC21692AAU
EC21692BAU
EC21692CAU
EC21692DAU
EC21693AAU
EC21693BAU
EC21693CAU
EC21693DAU
EC21698AAU
EC21698BAU
EC21698CAU
EC21698DAU
A200M9CJ
A200M9CW
A200M9CX
A200M9CE
Starters do not include heater packs. Order quantity of 3 heater packs. For Heater Pack Selection, see PG03300001E.
Cover Control . . . . . . . . . . . . . . . . . . . Page 33-119
Dimensions . . . . . . . . . . . . . . . . . . . . PG03300001E
Accessories . . . . . . . . . . . . . . . . . . . . PG03300001E
Modifications . . . . . . . . . . . . . . . . . . . Page 33-42
Renewal Parts . . . . . . . . . . . . . . . . . . PG03300001E
Technical Data . . . . . . . . . . . . . . . . . CA08102001E