Technical data

March 2009
CA08102001E For more information visit: www.eaton.com
33-177
NEMA Contactors & Starters
33
A200
Relays — Thermal and Fast Trip, Thermal Type A
Thermal Type A, Class 20,
Auto/Manual Reset
Type A Overload Relay
1-Pole Panel Mounting
Application Description
The Type A overload relay is designed
to protect industrial motors against
overload conditions. Using modern
block type, bimetallic design, this relay
will provide Class 20 operation in
either single- or 3-phase applications.
Features
■ Field selectable manual/auto reset
■ Alarm contract factory available
■ Class 20 — 600V design
■ Inverse time delay trip
■ Adjustable trip rating ± 15%
■ Color coded reset rod:
❑ Compensated (Gray)
❑ Non-compensated (Red)
Operation
The Type A overload relay is a bimetal-
lic actuated device. The bimetal ele-
ments are operated by precisely
calibrated heaters. The heater ele-
ments are connected either directly in
the circuit to be measured, or through
current transformers on applications
NEMA Size 5 and larger.
As the bimetals are heated by motor
current flow, a deflection force is pro-
duced. Upon a sustained level of
abnormal current flow, the deflection
becomes great enough to open the
snap-action output contact.
Automatic Reset
The Type A overload relay can be sup-
plied as an option on all A200 starters
to provide automatic reset operation.
The overload relay is always shipped
in the non-automatic mode. To set up
auto operation, reposition the reset
rod by loosening and re-tightening a
hold-down clamp at the base of over-
load relay.
Standards and Certifications
■ UL508
■ CSA
■ ANSI/NEMA ICS 2-222
Technical Data
Table 33-276. Control Contact Ratings
Product Selection
Heaters
Enter heaters as separate item by listing Catalog Number from tables,
Pages 33-181 – 33-182, as required per starter.
Relays
Table 33-277. Product Selection — Thermal Type A Overload Relay Selection
Note: For Alarm Contact (Form C), add Suffix B. Available only as factory modification on
Type A relay.
3-Pole Type B Overload Relay is a suitable alternative to a 3-Pole Type A Overload Relay in
Manual Reset Mode. For example, BA13JP for AA13P, BN23J for AN23A, etc. (See Page 33-175.)
AC
Volts
Normally
Closed
Normally
Open
Make Break Make Break
Three-Pole Control Contact Ratings
24 – 120
120 – 600
20A
2400 VA
2A
240 VA
.5A
600 VA
.5A
60 VA
One-Pole Control Contact Ratings
24 – 120
120 – 600
30A
3600 VA
3A
360 VA
10A
1200 VA
1A
120 VA
Motor Full
Load Amps
Panel Mounted Starter Replacement Price
U.S. $
Ambient Comp. Non-comp. Ambient Comp. Non-comp.
Catalog
Number
Catalog
Number
Catalog
Number
Catalog
Number
Single-Pole (One NC Contact)
.25 – 26.2
26.3 – 45
19 – 90
19 – 135
AA11P
AA21P
AA31P
AA41P
AN11P
AN21P
AN31P
AN41P
AA11A
AA21A
AA31A
AA41A
AN11A
AN21A
AN31A
AN41A
Three-Pole (One NC Contact)
.25 – 26.2
26.3 – 45
19 – 90
19 – 135
AA13P
AA23P
AA33P
AA43P
AN13P
AN23P
AN33P
AN43P
AA13A
AA23A
AA33A
AA43A
AN13A
AN23A
AN33A
AN43A
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 1CD1C