Technical data

March 2009
33-118
For more information visit: www.eaton.com CA08102001E
NEMA Contactors & Starters
33
Freedom, Full Voltage — Enclosed
Product Family Overview
Catalog Number Selection
Table 33-183. NEMA Freedom Line Enclosed Control Catalog Numbering System
Use for Sizes 0 – 3, HMCP 600V applications only.
Table 33-184. Magnetic Coil Codes (System Voltage)
When control power transformer modification codes (C1 – C11)
are used or when starter class includes CPT (i.e. ECN07, 18) see
Table 33-185 for system voltage code.
Table 33-185. Control Power Transformer Codes (System Voltage)
E C N 2 2 2 1 A A F -
Design
N = Freedom NEMA
2 = A200
Modification Codes
See Page 33-42 – 33-49
Coil Voltage and/or Control Transformers
See Tables 33-184 and 33-185
Class Table
01 = Non-reversing Contactor — 3-Pole 33-189
Non-reversing Contactor — 2-Pole 33-190
Non-reversing Contactor — 4-Pole 33-191
Non-reversing Contactor — 5-Pole 33-192
02 = Reversing Contactor — 3-Pole 33-193
05 = Non-combination Non-reversing Starter 33-194
06 = Non-combination Reversing Starter 33-195
07 = Non-combination Non-reversing Starter with CPT 33-196
08 = Non-combination Single-Phase Non-reversing Starter 33-197
16 = Combination Non-reversing Starter — Fusible
Disconnect
33-198,
33-287
Combination Non-reversing Starter — Non-fusible
Disconnect
33-199
Special Enclosure Combination Non-reversing
Starter —
Fusible/Non-fusible Disconnect
33-200
17 = Combination Reversing Starter — Fusible Disconnect 33-201
Combination Reversing Starter — Non-fusible
Disconnect
33-202
18 = Combination Reversing Starter — Fusible Disconnect
with CPT
33-203,
33-288
Combination Reversing Starter — Non-fusible
Disconnect with CPT
33-204
22 = Combination Non-reversing Starter — Circuit Breaker 33-205,
Special Enclosure Combination Non-reversing
Starter — Circuit Breaker
33-206
Disconnect Fuse Clip Ratings
A =
B =
C =
D =
E =
F =
None
30A/250V R
30A/600V R
60A/250V R
60A/600V R
100A/250V R
G =
H =
J =
K =
L =
M =
100A/600V R
200A/250V R
200A/600V R
400A/250V R
400A/600V R
600A/250V R
N =
P =
Q =
R =
S =
T =
600A/600V R
800A/600V L
1200A/600V L
1600A/600V L
2000A/600V L
by Description
HMCP/E or Breaker Ratings
A =
B =
C =
D =
E =
F =
W =
G =
None
3A
7A
15A
30A
50A
70A
100A
H =
J =
K =
L =
M =
N =
P =
Q =
150A
250A
400A
600A
800A
1000A
1200A
2000A
R =
T =
5 =
6 =
7 =
8 =
9 =
I =
3000A
by Description
3A
7A
15A
30A
50A
100A
Cover Control
Type 1 Non-comb., Table 33-186
All Others, Table 33-187
E22 Style Comb., Table 33-189
Contactors
3 = 3 Poles
Enclosure Type
1 =
2 =
3 =
4 =
5 =
6 =
7 =
8 =
9 =
Type 1 — General Purpose
Type 3R — Rainproof
Type 4 — Watertight (Painted Steel)
Type 4X — Watertight (304-Grade Stainless Steel)
Type 4X — Corrosion (Nonmetallic)
Type 7/9 — Bolted Hazardous Location
Type 7/9 — Threaded Hazardous Location
Type 12 — Dust-Tight
Type 4X — 316-Grade Stainless Steel
NEMA Size
A =
0 =
1 =
2 =
Size 00
Size 0
Size 1
Size 2
3 =
4 =
5 =
6 =
Size 3
Size 4
Size 5
Size 6
7 =
8 =
9 =
Size 7
Size 8
Size 9
Code Magnet Coil Code Magnet Coil Code Magnet Coil
A
B
C
D
E
G
H
J
120/60 110/50
240/60 220/50
460/60 440/50
575/60 550/50
208/60
550/50
277/60
208 – 240/60
K
L
M
P
Q
R
S
T
240/50
380/50
415/50
12V DC
24V DC
48V DC
125V DC
24/60
U
V
W
X
Y
Z
24/50
32/50
48/60
104 – 120/60
48/50
By Description
Code Primary Secondary
B
C
D
E
H
240/480 – 220/440 Wired for 240V
240/480 – 220/440 Wired for 480V
600/60 – 550/50
208/60
277/60
120/60 – 110/50
120/60 – 110/50
120/60 – 110/50
120/60
120/60
L
M
Q
R
S
380/50
415/50
208/60
240/480 – 220/440 Wired for 240V
240/480 – 220/440 Wired for 480V
110/50
110/50
24
24
24
T
U
V
W
X
600/60
277/60
380/50
415/50
240/480/600 Wired for 480V
24
24
24
24
120
Y
Z
240/480/600 Wired for 480V
By Description
24