Technical data

March 2009
33-112
For more information visit: www.eaton.com CA08102001E
NEMA Contactors & Starters
33
Freedom
Relays — C396 Electronic Overload
Table 33-179. C396 Overload for Integrated Use with Freedom NEMA
Contactors
Note: For NEMA Sizes 5 – 8, refer to Table 33-177, Current
Transformer Kits.
Discount Symbol 1CD1.
Discount Symbol 1CD7.
Panel mount only! Overload comes with integrated pass-through
holes for power wires. Bus Bar Kit (C396CBAR
or C396CBARXT, see
Table 33-181) and Lug Kit (C396CLUG) must be purchased separately
if customer prefers not to use pass-through capability.
Table 33-180. C396 Overload for Integrated Use with DP Contactors by
Feature Set
Discount Symbol 1CD-5C.
Accessories
Table 33-181. C396 Electronic Overload Accessories
Discount Symbol 1CD7.
Discount Symbol 1CD1.
Set of 3 lugs and hardware, 2 sets are required to wire line and load
sides. Bus Bar Kit (C396CBAR or C396CBARXT) is needed to use the
Lug Kit.
Bus bar kits do not include lugs. Order C396CLUG if lugs are needed
(3 lugs per kit).
The operator button is blue with the letters “RESET” printed in white.
The push rod is 4.72" long and can be cut to the desired length. This kit
can be used alone or in conjunction with the C396 Reset Bar Kit,
C396ARST, to increase the size of the reset area on the overload.
Reset Bar Kit (C396ARST) required to use the Remote Reset modules.
Note that all Freedom Starters come with Reset Bars.
When used in conjunction with a Stand-Alone C396 Overload Relay
(overloads with an “AX” suffix), style number of the overload must
end in a “B” or later.
Must be cut to proper length — uncut 4.72 inches (119.9 mm) long.
Enables a 22.5 mm operator to be mounted in a 30.5 mm holes —
1/16 to 7/32 inch (1.6 to 5.6 mm) panel thickness.
Dimensions . . . . . . . . . . Page 33-114, Page 33-115
FLA
Range
(Amps)
NEMA
Contactor
Frame Size
Description Catalog
Number
Price
U.S. $
45 mm Overload Frame Size
0.1 – 0.5
0.4 – 2.0
00, 0, 1
00, 0, 1
C396A2AP05SELFD
C396A2A002SELFD
1 – 5 00
0
1
C396A2A005SELF00
C396A2A005SELF0
C396A2A005SELF1
1.6 – 8 00
0
1
2
C396A2A008SELF00
C396A2A008SELF0
C396A2A008SELF1
C396A2A008SELF2
6.4 – 32 0
1
C396A2A032SELFB
C396A2A032SELFD
9 – 45 2 C396A2A045SELFG
65 mm Overload Frame Size
22 – 110 3 C396B2A110SELFK
110 mm Overload Frame Size — Stand-Alone
30 – 150 4 C396C2A150SELAX
FLA
Range
(Amps)
DP
Contactor Rating
Catalog
Number
Price
U.S. $
45 mm Overload Frame Size
0.1 – 0.5
0.4 – 2.0
1 – 5
1.6 – 8
6.4 – 32
9 – 45
15, 25, 30
15, 25, 30
15, 25, 30
15, 25, 30, 40
15, 25, 30, 40, 50
40, 50
C396A2AP05SELDC
C396A2A002SELDC
C396A2A005SELDC
C396A2A008SELDE
C396A2A032SELDF
C396A2A045SELDF
65 mm Overload Frame Size
15 – 75 60, 75 C396B2A075SELDG
Cat. No.
C396A2A008SELDC
Description Catalog
Number
Price
U.S. $
Reset Bar Kit
assembles to the top
of the overload to
increase reset area.
C396ARST
110 mm Lug Kit

C396CLUG
110 mm Bus Bar Kit

C396CBAR
110 mm XT Bus Bar
Kit

C396CBARXT
Remote Reset
24V DC

C396RR024DC
Remote Reset
24V AC

C396RR024AC
Remote Reset
120V AC

C396RR120AC
Remote Reset
240V AC

C396RR240AC
Mechanical Reset
with E22 Flush Push-
button and Mechani-
cal Push Rod

Plastic Black Bezel
Chrome Bezel
E22PB6N29L
E22P6N29L
Mechanical Push
Rod — for external
mechanical reset
E22MRL
Mounting Hole
Adapter Kit
E22ARK
C396ARST +
C396RR _ _ _ _ _
Assembled to a C396
Overload Relay