Technical data

33-52
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog CAT.201.01.T.E
January 2001
NEMA Contactors & Starters
33
3-Phase Magnetic Starters — Enclosed
Freedom Line
Vol. 2, Ref. No. [0068]
Catalog Number Selection
Table 33-102. NEMA Freedom Line Enclosed Control Catalog Numbering System
1
Refer to
Enclosed Control Product Guide,
P.G.3.02.T.E.
2
Use for Sizes 0 – 3, HMCP 600V applications only.
Table 33-103. Magnetic Coil Codes (System Voltage)
3
3
When control power transformer modification codes (C1C11) are
used or when starter class includes CPT (i.e. ECN07, 18) see table to the
right for system voltage code.
Table 33-104. Control Power Transformer Codes (System Voltage)
Modification Codes
Design
Class
NEMA
Page
Page
01 - Contactors
a
02 - Reversing Contactors a
05 - FVNR Starter, Non-combination 33-53
06 - Reversing, Non-combination 33-55
07 - FVNR Non-combination, with CPT 33-57
08 - Single-Phase FVNR (Freedom Only) a
16 - Combination with Disconnect Switch 33-58
17 - Reversing, Combination with Disconnect Switch 33-62
18 - Combination with Disconnect Switch, with CPT 33-65
22 - Combination with HMCP/E 33-67
23 - Reversing, Combination with HMCP/E 33-69
24 - Combination with HMCP/E with CPT 33-71
33 - Multispeed 2S2W Non-combination a
34 - Multispeed 2S1W CT or VT Non-combination a
35 - Multispeed 2S1W CH Non-combination a
36 - Multispeed with Disconnect Switch, 2S2W a
37 - Multispeed with Disconnect Switch, 2S1W CT or VT a
38 - Multispeed with Disconnect Switch, 2S1W CH a
39 - Multispeed with HMCP/E, 2S2W a
40 - Multispeed with HMCP/E, 2S1W CT or VT a
41 - Multispeed with HMCP/E, 2S1W CH a
42 - Autotransformer, Non-combination a
43 - Autotransformer, with Disconnect Switch a
44 - Autotransformer, with HMCP/E a
45 - Part-Winding, Non-combination a
46 - Part-Winding, with Disconnect Switch a
47 - Part-Winding, with Circuit Breaker a
48 - Y-D, Open Transition, Non-combination a
49 - Y-D, Open Transition, with Disconnect Switch a
50 - Y-D, Open Transition, with Circuit Breaker a
51 - Y-D, Closed Transition, Non-combination a
52 - Y-D, Closed Transition, with Disconnect Switch a
53 - Y-D, Closed Transition, with Circuit Breaker a
54 - Std Width Pump Panel, with Disconnect Switch a
55 - Std Width Pump Panel, with HMCP/E a
62 - Autotransformer Pump Panel, Disconnect Switch a
63 - Autotransformer Pump Panel, HMCP/E a
64 - Part-Winding Pump Panel, Disconnect a
65 - Part-Winding Pump Panel, Circuit Breaker a
68 - Duplex, Non-combination a
69 - Duplex, with Disconnect Switch a
70 - Duplex, with HMCP/E a
Enclosure Types
1 - Type 1 – General Purpose
2 - Type 3R – Rainproof
3 - Type 4 – Watertight (Painted Steel)
4 - Type 4X – Watertight (Stainless Steel)
5 - Type 4X – Corrosion (nonmetallic) (Section 9)
6 - Type 7/9 – Bolted Hazardous Location (Section 8)
7 - Type 7/9 – Threaded Hazardous Location (Section 8)
8 - Type 12 – Dust-Tight
9 - Type 12 – Dust-Tight with Safety Door Interlock
Disconnect Fuse Clip Ratings
None
30A/250V R
30A/600V R
60A/250V R
60A/600V R
100A/250V R
A -
B -
C -
D -
E -
F -
G -
H -
J -
K -
L -
M -
100A/600V R
200A/250V R
200A/600V R
400A/250V R
400A/600V R
600A/250V R
HMCP or Breaker Ratings
None
3A
7A
15A
30A
50A
A -
B -
C -
D -
E -
F -
G -
H -
J -
K -
L -
M -
100A
150A
250A
400A
600A
800A
N - NEMA
E - IEC
A - Advantage
L - Lighting
S - Solid-State
V - Vacuum
33-40
34-69
33-100
37-13
39-20
a
NEMA Size
A - Size 00
0 - Size 0
1 - Size 1
2 - Size 2
3 - Size 3
4 - Size 4
5 - Size 5
6 - Size 6
7 - Size 7
8 - Size 8
9 - Size 9
Cover Control
(Starters Only)
(See Pages 33-5033-51)
Number of Poles
(Contactors Only)
(See Pages 33-41 – 33-48)
Coil Voltage and/or Control Transformers
(See Tables Below)
N -
P -
Q -
R -
S -
T -
600A/600V R
800A/600V L
1200A/600V L
1600A/600V L
2000A/600V L
by Description
N -
P -
Q -
R -
T -
1000A
1200A
2000A
3000A
by Description
5 -
6 -
7 -
8 -
9 -
I -
3A
b
7A
b
15A
b
30A
b
50A
b
100A
b
E C N 2 2 2 1 A A F -
Code Magnet Coil Code Magnet Coil Code Magnet Coil
A
B
C
D
E
G
H
J
120/60 110/50
240/60 220/50
480/60 440/50
600/60 550/50
208/60
550/50
277/60
208 – 240/60
K
L
M
P
Q
R
S
T
240/50
380/50
415/50
12V DC
24V DC
48V DC
125V DC
24/60
U
V
W
X
Y
Z
24/50
32/50
48/60
104 – 120/60
48/50
By Description
Code Primary Secondary
B
C
D
E
H
240/480 – 220/440 Wired for 240V
240/480 – 220/440 Wired for 480V
600/60 – 550/50
208/60
277/60
120/60 – 110/50
120/60 – 110/50
120/60 – 110/50
120/60
120/60
L
M
Q
R
S
380/50
415/50
208/60
240/480 – 220/440 Wired for 240V
240/480 – 220/440 Wired for 480V
110/50
110/50
24
24
24
T
U
V
W
X
600/60
277/60
380/50
415/50
240/480/600 Wired for 480V
24
24
24
24
120
Y
Z
240/480/600 Wired for 480V
By Description
24
Tab3302.fm Page 52 Monday, October 23, 2000 10:07 PM