Technical data

33-46
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog CAT.201.01.T.E
January 2001
NEMA Contactors & Starters
33
3-Phase Magnetic Starters — Enclosed
Freedom/Advantage/IT/AF91 Lines
Vol. 2, Ref. No. [0062]
Modification Codes (Continued)
Table 33-88. P — Pilot Lights, Pushbuttons, Phase Relays, Potential
Transformers, Program Timer, Percentage Timer, Photocell (Continued)
1
Not available for IT Starters.
2
Consult factory for price.
Table 33-89. Q — IQ Products, WPoni, DN50
3
Not available for IT Starters.
Table 33-90. R — Relays, Resets, Overload Relay Modifications,
DeviceNet Modifications
4
Not available for IT Starters.
5
Consult factory for price.
Modification Catalog
Number
Suffix
Description Adder
U.S. $
Pilot Lights
(Continued)
P58 Pilot Light — Red BYPASS (AF91) 159.
P59
1
Pilot Light — Amber INVERTER
ENABLE (AF91)
159.
P60
1
Pilot Light — Red INVERTER
RUNNING (AF91)
159.
P61 Pilot Light — Green STOP 159.
P62
1
FORWARD/REVERSE Red Pilot Lights 315.
P63
1
UP/DOWN Red Pilot Lights 315.
P64
1
OPEN/CLOSE Red Pilot Lights 315.
P65
1
HIGH/LOW Red Pilot Lights 315.
P66
1
FAST/SLOW Red Pilot Lights 315.
P67 Green RUN Light 159.
P68 LED Bulbs (per light) 31.
P69 Blue OVERLOAD Light (AF91) 159.
Illuminated
Pushbutton
P27 Illuminated Pushbutton — Order by
Description
2
Phase Loss
Relay
P28 Phase Loss Relay 530.
Phase Reversal
Relay
P30 Phase Reversal Relay 530.
Phase
Unbalance
Relay
P32 Phase Unbalance Relay 650.
Phase
Monitoring
Relay
P34 Phase Monitoring Relay 1,110.
Phase Loss P36
1
Phase Loss Protection Omitted
(Advantage)
N/C
P37
1
Modification to Extend Phase Loss
Trip Time to 17 Seconds (Advantage)
N/C
Potential
Transformers
P39
1
Potential Transformer — Wired
L1 – L2
118.
P40
1
Potential Transformer — Wired
L1– L2 and L2 – L3
235.
P41
1
Potential Transformer — 3 Phases 351.
Pump
Controller
P42 Pump Controller for IT 1,005.
Program
Timers
P43 15-Minute Program Timer 530.
P44 24-Hour Program Timer 530.
P45 7-Day Program Timer with Day
Omission Feature
700.
Percentage
Timers
P47 15-Minute Percentage Timer 530.
P48 60-Minute Percentage Timer 530.
Photocell P70
1
Photoelectric Receptacle with
Photocell
406.
Modification Catalog
Number
Suffix
Description Adder
U.S. $
IQ Products Q14 IQ 220 with cable 1,515.
Q1 IQ 500 760.
Q3 MP3000 5,010.
Q5 IQ 4000 5,360.
IQ Data
Metering
Module
Q12
3
With IQ Data Metering Module 1,120.
WPoni Q8
3
WPoni (Advantage) 445.
Q9
3
WCTLponi (Advantage) 525.
DN50 Q13
3
DeviceNet Input/Output Module 1,500.
Modification Catalog
Number
Suffix
Description Adder
U.S. $
Ramp R1 Extended Ramp of IT 580.
Relay
4
R2 Overvoltage Relay 423.
R4 Omit Overload Relay (Deduct Price)
00 – 0 1 2 3 4 5 – 9
A – F G – H J – K L – M N P – S
-30. -30. -54. -90. -138. -504.
R7 Overload Relay — Order by
Description
5
Resets
4
R5 Change External Reset to Internal
Reset — Hole Covered with Plug
N/C
R6 Internal Reset — No Hole Plug N/C
R44 Manual Reset Only on Overload Relay 6.
R45 Auto Reset Only on Overload Relay 6.
R47 With Internal Trip Indicator (No Exter-
nal Reset) — Advantage
21.
R48 External Reset with External Trip Indi-
cator (Advantage)
97.
R49 With Alarm Module (Advantage)
(Bell Alarm)
151.
R71 N3R Reset Boot Added (NEMA 1/12
Only)
33.
Reversing
4
R54 Reversing Contactor/Starter
5
DeviceNet
Modification
R68 WPONIDNA — DeviceNet
Communication Interface
915.
R69 DeviceNet Interface
5
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . 1CD-1C