Technical data

CAT.201.01.T.E For more information contact Cutler-Hammer at:
www.ch.cutler-hammer.com/catalog
33-103
January 2001
NEMA Contactors & Starters
33
3-Phase Magnetic Starters — Enclosed
Advantage Line
Vol. 2, Ref. No. [0119]
Catalog Number Selection
Table 33-165. Advantage Line Enclosed Control Catalog Numbering System
1
Refer to
Enclosed Control Product Guide
, PG.3.02.T.E.
2
Use with Sizes L – 3, HMCP 600V applications only.
Table 33-166. Magnet Coil Codes (System Voltage)
3
3
When control power transformer modification codes (
C1
C11
) are
used or when starter class includes CPT (i.e. ECN07, 18), see
Table 33-167
for system voltage code.
Table 33-167. Control Power Transformer Codes (System Voltage)
Design
Class
01 - Contactors
02 - Reversing Contactors
05 - FVNR Starter, Non-combination
06 - Reversing, Non-combination
07 - FVNR Non-combination, with CPT
16 - Combination with Disconnect Switch
17 - Reversing, Combination with Disconnect Switch
18 - Combination with Disconnect Switch, with CPT
22 - Combination with HMCP/E
23 - Reversing, Combination with HMCP/E
24 - Combination with HMCP/E with CPT
33 - Multispeed 2S2W Non-combination
34 - Multispeed 2S1W CT or VT Non-combination
35 - Multispeed 2S1W CH Non-combination
36 - Multispeed with Disconnect Switch, 2S2W
37 - Multispeed with Disconnect Switch, 2S1W CT or VT
38 - Multispeed with Disconnect Switch, 2S1W CH
39 - Multispeed with HMCP/E, 2S2W
40 - Multispeed with HMCP/E, 2S1W CT or VT
41 - Multispeed with HMCP/E, 2S1W CH
42 - Autotransformer, Non-combination
43 - Autotransformer, with Disconnect Switch
44 - Autotransformer, with HMCP/E
45 - Part-Winding, Non-combination
46 - Part-Winding, with Disconnect Switch
47 - Part-Winding, with Circuit Breaker
48 - Y-D, Open Transition, Non-combination
49 - Y-D, Open Transition, with Disconnect Switch
50 - Y-D, Open Transition, with Circuit Breaker
51 - Y-D, Closed Transition, Non-combination
52 - Y-D, Closed Transition, with Disconnect Switch
53 - Y-D, Closed Transition, with Circuit Breaker
54 - Std Width Pump Panel, with Disconnect Switch
55 - Std Width Pump Panel, with HMCP/E
62 - Autotransformer Pump Panel, Disconnect Switch
63 - Autotransformer Pump Panel, HMCP/E
64 - Part-Winding Pump Panel, Disconnect
65 - Part-Winding Pump Panel, Circuit Breaker
68 - Duplex, Non-combination
69 - Duplex, with Disconnect Switch
70 - Duplex, with HMCP/E
a
a
33-104
33-105
33-106
33-107
33-109
33-111
33-112
33-113
33-114
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
Enclosure Types
1 - Type 1 – General Purpose
2 - Type 3R – Rainproof
3 - Type 4 – Watertight (Painted Steel)
4 - Type 4X – Watertight (Stainless Steel)
5 - Type 4X – Corrosion (nonmetallic) (Section 9)
6 - Type 7/9 – Bolted Hazardous Location (Section 8)
7 - Type 7/9 – Threaded Hazardous Location (Section 8)
8 - Type 12 – Dust-Tight
9 - Type 12 – Dust-Tight with Safety Door Interlock
Disconnect Fuse Clip Ratings
None
30A/250V R
30A/600V R
60A/250V R
60A/600V R
100A/250V R
A -
B -
C -
D -
E -
F -
G -
H -
J -
K -
L -
M -
100A/600V R
200A/250V R
200A/600V R
400A/250V R
400A/600V R
600A/250V R
HMCP/E or Breaker Ratings
None
3A
7A
15A
30A
50A
100A
150A
250A
400A
600A
800A
A = Advantage
NEMA Size
L - Lower 1
1 - Size 1
2 - Size 2
3 - Size 3
4 - Size 4
5 - Size 5
6 - Size 6
Page
Cover Control (Starters Only)
(Pages 33-50 – 33-51 and 33-101)
Number of Poles (Contactors Only)
Modification Codes
(See Pages 33-41 – 33-48)
Coil Voltage and/or Control Transformers
(See Tables Below)
N -
P -
Q -
R -
S -
T -
A -
B -
C -
D -
E -
F -
G -
H -
J -
K -
L -
M -
N -
P -
Q -
R -
T -
600A/600V R
800A/600V R
1200A/600V R
1600A/600V R
2000A/600V R
by Description
1000A
1200A
2000A
3000A
by Description
5 -
6 -
7 -
8 -
9 -
I -
3A
b
7A
b
15A
b
30A
b
50A
b
100A
b
E C A 2 2 2 1 A A F -
Code Magnet Coil Code Magnet Coil
F
N
120/60
110/50
Z
By Description
Code Primary Secondary Code Primary Secondary
B
C
D
E
240/480 – 220/440
Wired for 240V
240/480 – 220/440
Wired for 480V
600/60 – 550/50
208/60
120/60 – 110/50
120/60 – 110/50
120/60 – 110/50
120/60
H
L
M
X
Z
277/60
380/50
415/50
240/480/600
Wired for 480V
By Description
120/60
110/50
110/50
120
Tab3304.fm Page 103 Monday, October 23, 2000 10:12 PM