Technical data

June 2008
CA08102001E For more information visit:
www.eaton.com
37-3
Lighting Contactors
37
Open Control
CN35 Electrically Held
Auxiliary Contacts
CN35 Lighting Contactors include a
1NO maintaining auxiliary contact
mounted on right hand side (on 10A,
2- and 3-pole devices, auxiliary contact
occupies 4th power pole position — no
increase in width). The 10 – 60A
devices will accept additional auxiliary
contacts on the top and/or sides.
Auxiliary contact blocks are designed
for snap-on installation — fast, easy
installation (no tools required up to
60A). All auxiliary contacts are of the
bifurcated design with parallel circuit
paths. This redundant path provides
very high reliability. Auxiliary contacts
can be snapped on the side (up to 2
circuits — per auxiliary contact) and on
the top (up to 4 circuits). Auxiliary con-
tacts for larger contactors, 100 – 400A
sizes, will accept side mounted auxilia-
ries only and easily attach to the side
of the contactor with 2 screws.
Auxiliary Contacts —
10 – 60A Contactors
Auxiliary Contacts —
100 – 400A Contactors
Contact Configuration Code
This 2-digit code is found on the auxil-
iary contact to assist in identifying the
specific contact configuration. The first
digit indicates the quantity of NO con-
tacts and the second indicates the
quantity of NC contacts.
Side Mounted Top Mounted
Base Auxiliary Contact
Cat. No. C320KGS42
Auxiliary Contact
Cat. No. C320KGS22
Table 37-3. Auxiliary Contacts
10
60A Contactors
For Reference Only — not part of Catalog Number. See below left.
Cannot be added to contactors or starters mounted in Box 1 (NEMA Type 1).
Table 37-4. Auxiliary Contacts — 100 – 400A Contactors
For Reference Only — not part of Catalog Number. See below left.
NO-NC occupies two positions — L2 & L3 or R2 & R3. See
Page 37-4
.
Table 37-5. Auxiliary Contact Ratings (Amperes)
Description Contact
Configuration
Code
Catalog
Number
Price
U.S. $
Side Mounted
1NO
1NC
10
01
C320KGS1
C320KGS2
1NO-1NC
2NO
2NC
11
20
02
C320KGS3
C320KGS4
C320KGS5
Top Mounted
1NO
1NC
10
01
C320KGT1
C320KGT2
1NO-1NC
2NO
2NC
11
20
02
C320KGT3
C320KGT4
C320KGT5
3NO
2NO-1NC
1NO-2NC
3NC
4NO
30
21
12
03
40
C320KGT9
C320KGT10
C320KGT11
C320KGT12
C320KGT13
3NO-1NC
2NO-2NC
1NO-3NC
4NC
31
22
13
04
C320KGT14
C320KGT15
C320KGT16
C320KGT17
Circuit Contact
Configuration
Code
100A Contactors 200 & 300A Contactors Price
U.S. $
Catalog
Number
Catalog
Number
Base Auxiliary Contacts — 100 – 400A Contactors
NO
NO-NC
10
11
C320KGS31
C320KGS32
C320KGS41
C320KGS42
Circuit Contact
Configuration
Code
Catalog
Number
Price
U.S. $
Auxiliary Contacts — 100 – 400A Contactors
NO
NC
NO-NC
10
01
11
C320KGS20
C320KGS21
C320KGS22
Current AC Volts
120V 240V 480V 600V
NEMA A600
Make & Interrupting
Break
Continuous
60.0
6.0
10.0
30.0
3.0
10.0
15.0
1.5
10.0
12.0
1.0
10.0
NEMA P300
Continuous Thermal Rating: 5 Amperes
DC Volts Make/Break Amperes
125
250
1.10
0.55
Discount Symbol . . . . . . . . . . . . . . . . . . . . .
1CD-1C