Technical data
June 2008
CA08102001E For more information visit: www.eaton.com
37-21
Lighting Contactors
37
UL Rated AC Contactors
Product Family Overview
Catalog Number Selection
Table 37-43. Enclosed Lighting Contactor Catalog Numbering System
For normally closed poles see Page 37-36.
C30CN available in 30A only.
Enclosures
Lighting contactors are available open
or mounted in Type 1, 3R, 4, 4X, 12 or
7/9 enclosures.
Type 1 is for indoor, general purpose
for personal protection. Knock-outs
are provided in the top and bottom for
conduit entry.
Type 3R is for outdoor applications
and rated for rain, sleet and external
ice buildup. Type 3R enclosures have
knockouts in the bottom and provi-
sions for a hub in the top.
Type 4 and 4X are for mounting indoor
or outdoor and provide protection
from splashing water, hose-directed
water and wind-blown dust. Water-
tight conduit hubs are provided in the
top and bottom of Type 4X enclosures.
The standard Type 4X enclosures are
made of 304-Grade stainless steel, pro-
viding corrosion protection. 316-Grade
stainless steel construction is available
as an upgrade option.
Type 12 enclosures are for indoor
mounting and protect from dripping
liquids, falling dirt and dust. No knock-
outs or hubs are provided with Type 12
enclosures.
Type 1, 3R, 4 and 12 enclosures are
painted with a polyester urethane
powder coat paint meeting UL require-
ments and the color is ANSI 61 gray.
Type 1 enclosures have knockouts for
cover controls. All the other Types
have holes plugged, ready for cover
controls. Type 7/9 is also available for
explosion proof applications. Please
contact the factory for additional
details.
E C L 1 2 D 1 A 3 E - X
Design
L = CN35 or A202 Lighting Contactor
C = C30CN Lighting Contactor
Class Table
03 = Non-combination Electrically Held
Lighting Contactor
37-45, 37-47
04 = Non-combination Mechanically Held/
Magnetically Latched Lighting Contactor
37-46, 37-48
12 = Combination Electrically Held Lighting
Contactor — Fusible Disconnect
37-49
13 = Combination Magnetically Latched
Lighting Contactor — Fusible Disconnect
37-49
14 = Combination Electrically Held Lighting
Contactor — Thermal Magnetic
Circuit Breaker
37-50
15 = Combination Magnetically Latched
Lighting Contactor — Thermal Magnetic
Circuit Breaker
37-50
Ampere Size
A = 10A
B = 20A
C = 30A
D = 60A
E = 100A
F = 200A
G = 300A
H = 400A
J = 600A
Enclosure Types
1 = Type 1 — General Purpose
2 = Type 3R — Rainproof
3 = Type 4 — Watertight (Painted)
4 = Type 4X — Watertight (304-Grade Stainless Steel)
6 = Type 7/9 — Explosion Proof
8 = Type 12 — Dust-Tight
9 = Type 4X — Watertight (316-Grade Stainless Steel)
Coil Voltage
A = 120/60 110/50
B = 240/60 220/50
C = 480/60 440/50
D = 600/60 550/50
E = 208/60
G = 550/50
H = 277/60
J = 208 – 240/60
K = 240/50
L = 380/50
M = 415/50
P = 12V DC
Q = 24V DC
R = 48V DC
S = 125V DC
T = 24/60
U = 24/50
V = 32/50
W = 48/60
X = 104 – 120/60
Y = 48/50
Z = By Description
Modification Codes
(See Page 37-22 and Page 37-33)
Number of Poles
1, 2, 3, 4, 5, 6, 7, 8, 9 = Poles Required
A = 10 Poles
B = 12 Poles
C = 20 Poles
Combination Devices = 3-Pole Only
Disconnect Fuse Clip Ratings
A = None
B = 30A/250V R
C = 30A/600V R
D = 60A/250V R
E = 30A/600V R
F = 100A/250V R
G = 100A/600V R
H = 200A/250V R
J = 200A/600V R
K = 400A/250V R
L = 400A/600V R
M = 600A/250V R
N = 600A/600V R
P = 800A/600V R
T = By Description
Thermal-Magnetic Breaker Ratings
A = None
D = 20A
E = 30A
F = 60A
G = 100A
H = 200A
J = 300A
K = 400A
L = 600A
M = 800A
T =By
Description