Specifications

DEMAND-CONTROLLED
VENTILATION
Usually the input ventilation air is divided on the
basis of the size of the various rooms.
The fresh outdoor air to those rooms is really
needed. That can be achieved with demand
controlled ventilation based on occupation (CO
2
measurement) or time programming (clock
function). A TNO certificate of equivalence
indicates that the
EPC advantage from such a controlled demand
system is 0.072 (2-zone time control) to 0.081(2-
zone CO
2
control).
HOW IT WORKS
When the air quality is good, there is no need
for ventilation. The air quality deteriorates when
people are present, for instance in the living room.
In that case, first the available ventilation air will
be sent to the living room in an intelligent manner.
Only when that appears to be insufficient, the
quantity of ventilation air will be increased. That
means customised ventilation; the available
ventilation air is sent to the room where the
ventilation air is needed. A lower ventilation flow
rate means a lower energy consumption and a
lower sound level.
REMOTE CONTROL CBB
Communication between the various
components is arranged through the Zigbee
protocol. The Zigbee protocol is a wireless
communication system. All components, so also
the remote control CBB (Control Panel Brink), are
connected to a wall socket.
OPERATION
Automatic based on presence (CO
2
measurement). CO
2
sensors determine the
ventilation air flow rate. At night, the
ventilation in the living room is reduced to the
minimum and, conversely, can be increased in
the bedrooms, without the high flow rate
causing additional noise nuisance.
Automatic based on a time program (clock
function). A menu enables adjustment of the
control damper settings for every day.
The user can set six time blocks per day.
Manual control. The fan setting can directly be
changed by turning the rotary knob on the
remote control CBB.
ACCESSORIES FOR BALANCED
VENTILATION WITH HEAT RECOVERY
Brink Climate Systems has developed and
selected appliance-specific accessories that can be
used to create an excellent installation. Starting
points are quality and ease of use and assembly.
I To dwelling
II To atmosphere
III From dwelling
IV From atmosphere
V Electric connections
VI Condensate discharge
KEY
Renovent HR Medium and Large 4b R
Renovent HR Medium and Large 2b/2o R
Renovent HR Small 4b R
Renovent HR Medium and Large 3b/1o R
Type A B C D E F G H I J K L M
Small 213 77 79 560 75 125 45 600 50 210 290 455 168
Medium 321 121 165 675 89 99 45 602 210 385 420 445 -
Large 336 126 165 675 89 114 53 602 220 385 430 455 -
DIMENSIONS RENOVENT HR SMALL, MEDIUM AND LARGE (IN MM)
OpenTherm
Control box
Renovent
Sleeping
zone
CO
2
sensor
Damper
Control signal
Living zone
CO
2
sensor
OpenTherm
Control box
Renovent
Sleeping
zone
Damper
Control signal
Living zone
Clock
Setup with CO
2
-sensor Setup with clock function