Specifications
7
KEY
1. Heated outdoor air to the bedroom and the sitting
room
2. Discharge foul air
3. Discharge foul air from kitchen, bathroom and toilet
4. Supply outdoor air
5. Filters
6. Heat exchanger
7. Control pcb
8. Display
9. Direct current fans for constant volume
10. Condensate discharge
TECHNICAL SPECIFICATIONS
Appliance | Small | Medium | Large
Ventilation capacity at 150 Pa [m
3
/h] | Maximum 180 | Maximum 300 | Maximum 400
Rated power [W] | 120 at 150 m
3
/h | 175 at 300 m
3
/h | 300 at 400 m
3
/h
(dependent on setting) | (at 150 Pa) | (at 150 Pa) | (at 150 Pa)
Dimension duct connection [mm] | Ø 125 | Ø 150 and Ø 160 | Ø 160 and Ø 180
H x W x D [mm] | 600 x 560 x 290 | 602 x 675 x 420 | 602 x 675 x 430
| (with bypass 500) | (with bypass 510)
Weight [kg] | 25 | 31 | 32
Temperature efficiency [%] | 95 | 95 | 95
Settings display
The appliances come with a display for setting
and reading out functions for increased ease of
installation. A cable kit and a computer
program are available for servicing purposes.
Naturally 95% efficiency
The synthetic heat exchanger
transfers 95% of the heat, which
makes further heating of the
ventilation air superfluous (measured
under NEN 5138). The EPS
contribution is approx. 0.3.
www.brinkclimatesystems.ie
High comfort, low-energy
ventilation
1
2
4
3
5
6
10
7
8
9