Specifications
BRINK AIR DISTRIBUTION SYSTEM
Brink Climate Systems has developed a
completely new synthetic air distribution
system for balanced ventilation with heat
recovery; a modular system composed of a
semi-circular, semi-rigid duct, various
accessories and two manifolds, one for
exhaust and one for supply. The height of
the semi-circular, semi-rigid is only 50 mm
and the flow rate is 30-35 m
3
/h with a flow
velocity of about 3 m/s. When 60 m
3
/h is
16
Brink Air Excellent certified to IS EN 13141-7 – Performance
testing of products for residential ventilation – central
mechanical supply and exhaust ventilation system packages
with heat recovery used in single dwelling. (Approved
procedure for DEAP)
Air restrictor
• Placed in the couplers in the
manifold to commission the
system
• Dependent upon the
resistance in the system
• The surface area of the
openingcan be read from a
table
Manifold
Insulated to reduce noise
3 types:
• DN 125 manifold 5 couplers
• DN 150 manifold 10 couplers
• DN 180 manifold 15 couplers
Opening for inspection and
cleaning
Flexible Duct
• Strong due to semi-circular form
• Maximum space required 50 mm
• Smooth inner surface
• Cleaning with a brush
Air distribution
system for balanced
ventilation with
heat recovery
www.brinkclimatesystems.ie
required, two ducts should be used. The
system is “plug and play”. The semi-circular
duct can be connected to the manifold and
diffusers with a wide range of accessories.
The bending radius of the duct is >200 mm
(horizontal) and >150 mm (vertical). The
diagram below depicts a complete system
with a heat recovery unit and air distribution
system, including two manifolds, air supply
and extract ducts, couplers and diffusers.
The duct is antistatic and has antibacterial
properties.