Specifications

BRINK AIR DISTRIBUTION SYSTEM
Brink Climate Systems has developed a
completely new synthetic air distribution
system for balanced ventilation with heat
recovery; a modular system composed of a
semi-circular, semi-rigid duct, various
accessories and two manifolds, one for
exhaust and one for supply. The height of
the semi-circular, semi-rigid is only 50 mm
and the flow rate is 30-35 m
3
/h with a flow
velocity of about 3 m/s. When 60 m
3
/h is
16
Brink Air Excellent certified to IS EN 13141-7 – Performance
testing of products for residential ventilation – central
mechanical supply and exhaust ventilation system packages
with heat recovery used in single dwelling. (Approved
procedure for DEAP)
Air restrictor
Placed in the couplers in the
manifold to commission the
system
Dependent upon the
resistance in the system
The surface area of the
openingcan be read from a
table
Manifold
Insulated to reduce noise
3 types:
• DN 125 manifold 5 couplers
• DN 150 manifold 10 couplers
• DN 180 manifold 15 couplers
Opening for inspection and
cleaning
Flexible Duct
• Strong due to semi-circular form
• Maximum space required 50 mm
• Smooth inner surface
• Cleaning with a brush
Air distribution
system for balanced
ventilation with
heat recovery
www.brinkclimatesystems.ie
required, two ducts should be used. The
system is “plug and play”. The semi-circular
duct can be connected to the manifold and
diffusers with a wide range of accessories.
The bending radius of the duct is >200 mm
(horizontal) and >150 mm (vertical). The
diagram below depicts a complete system
with a heat recovery unit and air distribution
system, including two manifolds, air supply
and extract ducts, couplers and diffusers.
The duct is antistatic and has antibacterial
properties.