Specifications
11
pp
KEY SLEEVES RENOVENT HR
Description Ø 125 mm < 180 m
3
/h Ø 150 mm < 250 m
3
/h Ø 160 mm 250 - 325 m
3
/h Ø 180 mm > 325 m
3
/h
1 = Ventilation roof sleeve (output) D125 •
Ventilation roof sleeve (output) D150 • •
Ventilation roof sleeve (output) D166 • •
2 =
Ventilation input (wall) D125
•
Ventilation input (wall) D150
•
•
Ventilation input (wall) D180
•
•
3 =
4 =
HR duct D125
•
HR duct D150 •
Thermally insulated hose (D160) •
HR duct D180
•
5 =
Adapter 150-125 and coupler D125 •
Adapter 180-150 and coupler D150 •
Adapter 160-150 and coupler D150 •
Adapter 150-125 and coupler D125 •
Adapter 180-160 and coupler D180 •
2
3
4
5
INSULATED DUCT
TERMINATION COWLS FOR
HRV INSTALLATIONS
To prevent condensation problems, it is
important to use sleeves that have specially
been developed for ventilation systems with
Brink HR heat recovery. Brink developed a
range of sleeves with internal insulation.
These combine perfectly with the HR heat
recovery duct system and with the thermal
hose from the connection kits.
COMMISSIONING OF SYSTEM
The commissioning of the system is the most
important part of the process. The commissioning
process ensures that the system complies with the
current Part F (Ventilation) building regulations. It is
not enough to have 0.5 air changes per hour
within the dwelling. The system must be balanced
to comply with correct airflow extraction rates from
kitchens and bathrooms etc. Commissioning
should be carried out with a calibrated anenometer
and a commissioning certificate showing the
airflows should be presented to the owner. It is
important to remember that MVHR systems are
designed primarily as ventilation systems, the heat
recovery aspect is to provide energy efficiency
within the dwelling but ventilation is the primary
objective. A system that is not correctly
commissioned will not function correctly.
INSTALLATION
The Brink Renovent HR ventilation unit is
characterised by a compact assembly format. All air
connections are located on the upper face. The air
connections provide approved flexible capabilities.
The insulating noise-absorbing connector can be
rotated to suit requirements; thus facilitating
assembly of the air duct to the unit, while
simultaneously preventing noise transmission
through the air distribution system. Brink operate
an installation training program for installers. Brinks
recommend you use an Brink registered installer
APPENDIX Q - SAP / DEAP
For energy assessors, The Brink Renovent HR-L
is independently tested and registered on the
Appendix Q listing. Also, The Brink Air Excellent low
profile semi rigid duct is also tested and listed on
the Appendix Q register. It is eligible for energy
calculations performed with the SEI-DEAP or the UK
Energy SAP software. The Brink Renovent HR-M has
a Specific Fan Power from 0.49 W/l/s @ 90%.
www.brinkclimatesystems.ie