Manual

3
103
104 A
Installaon Guide
102 B
102 A
104 B
The 4” Angle Series Top of Pole Mount does not come standard with the liing bracket and chain hoist.
If you choose to add this opon, follow steps 101 to 104 to install the liing assembly.
101: With the 4" Sch 40 or Sch 80 steel pipe installed in the ground, slide the pole cap
over the pipe.
102: Place the liing insert into the top of the pipe unl it sits ush. Place the liing
bracket into the liing insert with the eye facing south.
103: Hang a 1 ton or greater chain fall hoist from the liing eye.
104: Hang the U-Bracket Assembly on the Chain Hoist.
101
105: If you do not have a
chain fall hoist, install pole
cap at the top of the pole, in-
sert the 5/8” x 7” bolt, two
5/8” at washers and 5/8”nut
and four 1/2” x 1” set screws.
Tighten all. Proceed with in-
stallaon of all components at
the top of the pole.
106: Aach the Tilt Adjuster
Handle to the tab on the Back
Plate with the 1/2” x 1 1/2”
Bolt, two 1/2” at washers
and 1/2” Nylock Nut.
105
106