Specifications
134 IBM Flex System p260 and p460 Planning and Implementation Guide
Consider the scenario of dual-FC, dual-SAN switch redundancy, connected with
storage attached through a SAN for an p460. In this scenario, the OS has four
paths to each storage, and the behavior of the multipathing driver might vary,
depending on the storage and switch type. This scenario is one of the best
scenarios for high availability. The two adapters prevent an adapter fault, the two
switches prevent the case of a switch fault or firmware upgrade, and, as the SAN
has two paths to each storage device, the worst scenario is the failure of the
complete storage. Figure 5-4 shows this scenario.
Figure 5-4 Dual-FC and dual-SAN switch redundancy connection, as applied to the IBM Flex System p460
Compute Node
This configuration might be improved by adding multiple paths from each Fibre
Channel switch in the chassis to the SAN, which protects against a cable failure.
Chassis
Compute node
DS3400 Storage
V7000 Storage
SAN switch
SAN switch
Storage Area
Network
FC switch
FC switch
FC adapter
FC adapter