Technical information
Polycom CMA System Release Notes
Version 5.3
24
Interop-MCU SSGSE-7187 5.0 In some cases a conference
cannot be copied after it has
been terminated. This happens
because when the conference
terminates, the bridge sends
notifications about participants
being removed from the
conference before the
notification about the terminated
conference itself. The Polycom
CMA system then removes these
participants from the conference
before setting the conference
status to "finished". This causes
the finished conference to have
no participants.
Copy a conference before it ends
to make sure all participant are
still present.
Interop-MGC SSGSE-9008 5.3 The Extend Duration function
does not work on a scheduled
conference that uses a Polycom
MGC system as the bridge. The
call will end at the originally
scheduled end time.
None
Interop-MGC SSGSE-7209 5.0 When a MGC-scheduled
conference ends at its scheduled
end time, some of the
participants may be removed.
Copying the conference at this
time may result in a conference
with an incomplete list of
participants. This behavior is not
seen consistently and is not seen
if the conference is terminated
before its scheduled end time.
MGC-scheduled conferences
should be copied before they’re
end time (either before the
conference is launched or when
it's still ongoing).
Interop-
Microsoft
SSGSE-8839
SSGE-1089
4.1.1 Installing the Polycom
Scheduling Plugin for Microsoft
Outlook plugin causes some
Outlook instabillty.
None
Interop-
Microsoft
SSGSE-8764 5.3 Auto-discovery for Single
Sign-on fails when integrating
with a Windows Server 2008
Active Directory environment
with parent and child domains.
None
Interop-RMX SSGSE-8723 4.1.4 After some time during a 4M
conference scheduled on a
Polycom RMX 1500 bridge, all
H.323 participants are
disconnected.
None