Specifications

10-5
RS-232 Interface
RS-232 Host Parameters (continued)
Selecting the ICL, Fujitsu, Wincor-Nixdorf Mode A, Wincor-Nixdorf Mode B, or OPOS
terminal enables the transmission of code ID characters listed in Table 10-3. These code
ID characters are not programmable and are separate from the Transmit Code ID feature.
Do not enable the Transmit Code ID feature for these terminals.
Table 10-3. Terminal-Specific Code ID Characters
Parameter ICL Fujitsu
Wincor-
Nixdorf
Mode A
Wincor-
Nixdorf
Mode B/OPOS
Olivetti Omron
UPC-A AAA A A A
UPC-E EEC C C E
EAN-8/JAN-8 FF FF B B B FF
EAN-13/JAN-13 FFA A A F
Code 39 C <len> None M M M <len> C <len>
Codabar N <len> None N N N <len> N <len>
Code 128 L <len> None K K K <len> L <len>
I 2 of 5 I <len> None I I I <len> I <len>
Code 93 None None L L L <len> None
D 2 of 5 H <len> None H H H <len> H <len>
UCC/EAN 128 L <len> None P P P <len> L <len>
MSI None None O O O <len> None
Bookland EAN FFA A A F
Trioptic None None None None None None
Code 11 None None None None None None
IATA H<len> None H H None None
Code 32 None None None None None None