170
Index
3. Run EMC TestSMIProvider and run the command ‘dv’. Make sure all array
are discovered without any errors.
4. Make sure Performance frequency is set to non-off value in Wrench Icon for
Storage Array in Profiler (i.e. Performance is turned on).
5. Make sure there are instances for class name
CIM_BlockStorageStatisticalData when enumerating instance names (ein).
To do this, do the following:
6. Run Tek-Tools testProvider or EMCs testSMIProvider (Logging In
instructions above in Tools section).
7. Type ein for command.
8. Type CIM_BlockStorageStatisticalData for Class Name.
If no instances are returned, follow the instructions on resetting EMC provider
(How do I reset EMC provider?). Once complete, repeat steps 1-3 again.
Q: I am getting WriteHitIOs always zero for the LUNs even though cache is
enabled on CLARiiONs. Why?
A: This is due to a bug in the provider code. EMC will fix it in version 4.2.1
expected in July 2010. But the fix will only address CLARiiONs with flare code
30 or above.
Q: How do I get data for a CX600?
A: Per EMC, they do not support flare code 16 (2.16.x.x.x). The array must be
upgraded to 19, 22, or 24 with all the latest patches for that release
Q: I get the following DEP error from windows for the SMI-s provider, how
do I fix it?
A: To enable DEP for the SMI-s provider, do the following: