Product guide
NeXtScale nx360 M4 38
Physical and electrical specifications
NeXtScale nx360 M4 dimensions:
Width: 216 mm (8.5 in.)
Height: 41 mm (1.6 in.)
Depth: 659 mm (25.9 in.)
Maximum weight: 6.05 kg (13.31 lb)
NeXtScale n1200 enclosure dimensions:
Width: 447 mm (17.6 in.)
Height: 263 mm (10.4 in.)
Depth: 915 mm (36 in.)
Fully configured (stand-alone): 112 kg (247 lb), empty chassis 28 kg (62 lb)
Supported environment
The NeXtScale nx360 M4 compute node complies with ASHRAE class A3 specifications.
Power on:
Temperature: 5 °C - 40 °C (41 °F - 104 °F)
Humidity, non-condensing: -12 °C dew point (10.4 °F) and 8% - 85% relative humidity
Maximum dew point: 24 °C (75 °F)
Maximum altitude: 3048 m (10,000 ft)
Maximum rate of temperature change: 5 °C/hr (41 °F/hr)
Power off:
Temperature: 5 °C to 45 °C (41 °F to 113 °F)
Relative humidity: 8% - 85%
Maximum dew point: 27 °C (80.6 °F)
Storage (non-operating):
Temperature: 1 °C to 60 °C (33.8 °F to 140 °F)
Altitude: 3050 m (10,006 ft)
Relative humidity: 5% - 80%
Maximum dew point: 29 °C (84.2 °F)
Shipment (non-operating):
Temperature: -40 °C to 60 °C (-40 °F to 140 °F)
Altitude: 10,700 m (35,105 ft)
Relative humidity: 5% - 100%
Maximum dew point: 29 °C (84.2 °F)
Electrical requirements
100 - 127 (nominal) V AC; 50 Hz or 60 Hz; 6.8 A
200 - 240 (nominal) V AC; 50 Hz or 60 Hz; 5.0 A
Input kilovolt-amperes (kVA) (approximately):
Minimum configuration: 0.1 kVA
Maximum configuration: 6.0 kVA