Power supplies
The NeXtScale n1200 enclosure supports up to six redundant hot-plug power supplies, providing N+N or
N+1 redundancy Power policies with no redundancy is also supported. These High Efficiency (HE)
Platinum AC power supplies are 80 PLUS Platinum certified to allow for the best efficiency values of your
data center. The following table lists the supported power supply option.
Table 24. Power supplies
Part number Feature code Description Min / Max
supported
Chassis model
where used
00Y8569 A41T CFF 900W Power Supply 6 / 6 A2x
00Y8652 A4MM CFF 1300W Power Supply 2 / 6 A3x, A4x
The power supply options have the following features:
Supports N+N or N+1 Power Redundancy, or Non-redundant power configurations to support higher
density
Power management controller and configured through the Fan and Power Controller
Integrated 2500 RPM fan
80 PLUS Platinum certified
Built-in overload and surge protection
900W power supply specifications:
Supports dual-range voltage: 100 - 240 V
100 - 127 (nominal) V AC; 50 or 60 Hz; 6.8 A (maximum)
200 - 240 (nominal) V AC; 50 or 60 Hz; 5.0 A (maximum)
1300W power supply specifications:
Supports high-range voltage only: 200 - 240 V
200 - 240 (nominal) V AC; 50 or 60 Hz; 6.9 A (maximum)
Integrated virtualization
The server supports VMware vSphere (ESXi), which is installed on a USB memory key. The key is
installed in a USB socket inside the server. The following table lists the virtualization options.
Customized VMware vSphere images can be downloaded from:
http://ibm.com/systems/x/os/vmware/
Table 25. Virtualization options
Part number Feature
code
Description Maximum
supported
41Y8298 A2G0 Blank USB Memory Key for VMware ESXi Downloads 1
41Y8382 A4WZ USB Memory Key for VMware ESXi 5.1 Update 1 1
41Y8385 A584 USB Memory Key for VMware ESXi 5.5 1