Product guide

NeXtScale nx360 M4 23
If you do not use the 3.5-inch RAID cage or you are using 2.5-inch or 1.8-inch drives in the nx360 M4,
then the internal drives will be connected to a separate controller than the drives in the storage tray and
you will not be able to form a RAID array spanning both internal drives and drives in the storage tray. The
internal drives are connected to the ServeRAID C100 controller as indicated in the above table.
Note: It is not a supported combination to have the Storage Native Expansion Tray with 7 drives along
with two 2.5-inch SAS drives installed in the nx360 M4. This is because the ServeRAID C100 (which
would be required to drive the two internal drives) does not support SAS drives. The use of 2.5-inch SATA
drives are supported however.
Controller specifications
The ServeRAID H1110 adapter has the following specifications:
Four internal 6 Gbps SAS/SATA ports.
One x4 mini-SAS internal connector (SFF-8087).
6 Gbps throughput per port.
Based on LSI SAS2004 6 Gbps RAID on Chip (ROC) controller.
PCIe 2.0 x4 host interface.
Supports RAID 0, 1, 1E, and 10.
SAS and SATA drives are supported, but the mixing of SAS and SATA in the same integrated volume
is not supported.
Supports up to two integrated volumes.
Supports up to two global hot-spare drives.
Supports drive sizes greater than 2 TB for RAID 0, 1E, and 10 (not RAID 1).
Fixed stripe size of 64 KB.
The ServeRAID M1115 adapter has the following specifications:
Eight internal 6 Gbps SAS/SATA ports
Two x4 mini-SAS internal connectors (SFF-8087)
Supports RAID levels 0, 1, and 10
Supports RAID levels 5 and 50 with optional M1100 Series RAID 5 upgrade, 81Y4542
6 Gbps throughput per port
PCIe 3.0 x8 host interface
Based on the LSI SAS2008 6 Gbps ROC controller
The N2115 SAS/SATA HBA has the following features and specifications:
LSI SAS2308 6 Gbps I/O controller
PCI low profile, half-length - MD2 form factor
PCI Express 3.0 x8 host interface
Eight internal 6 Gbps SAS/SATA ports (support for 6, 3, or 1.5 Gbps speeds)
Up to 6 Gbps throughput per port
Two internal x4 Mini-SAS connectors (SFF-8087)
Non-RAID (JBOD mode) support for SAS and SATA HDDs and SSDs (RAID not supported)
Optimized for SSD performance
High-performance IOPS LSI Fusion-MPT architecture
Advanced power management support
Support for SSP, SMP, STP, and SATA protocols
End-to-End CRC with Advanced Error Reporting
T-10 Protection Model for early detection of and recovery from data corruption
Spread Spectrum Clocking for EMI reductions