User guide

4. 2 custom cables are required to go from the punch block to the RJ45 on the APX 7500 Consolette. The 2 custom
cables must be made in the field. Each of the custom cables consists of a CAT5 cable, terminate one end in a
standard RJ45 connection and strip the other end to go to the punchblock. For cable specifications on the 2
custom cables please refer to the MCC 5500 Dispatch Console Installation and Service Manual Revision
(221560G-10) contained on MOL under the Resource Center / Product Information / Manuals / Dispatch
Consoles / MCC 5500 Dispatch Console.
ORDERING REQUIREMENTS WHEN USING APX 7500 MOBILE IN A TRAY (O5 CONTROL HEAD / REMOTE
MOUNT) --- WITH THE MCC 5500 DISPATCH CONSOLE :
The MCC 5500 Dispatch Console R2.7 and beyond supports the APX 7500 Mobile in a Tray (O5 Control Head, Remote
Mount). However, in this configuration the use of a Digital Junction Box (DJB) is not supported only direct connection is
supported.
In this configuration the MCC 5500 Dispatch Console acts a Virtual Control Head for the APX 7500 Mobile in a Tray
(O5 Control Head, Remote Mount) supporting the following features:
ASTRO IDs
All mode changes
All soft keys programmed on the radio
PTT ID or Alias will display in the Activity Log Window
NOTE: In this configuration, all decoding of MDC 1200 and ASTRO IDs is done at the radio and not the MCC 5500
Dispatch Console. The MCC 5500 Dispatch Console will only display what is displayed on the control head of the radio.
For this configuration the following is required:
1. APX 7500 Mobile required options: G67 (Remote Mount) -- must have.
2. APX firmware R10.00.00 or greater
3. MCC 5500 Dispatch Console R2.7 or greater
4. MCC 5500 DAP II (L3550 or L3551) with SB9600 iButton (TT05248AA or DDN9680)
5. APX Direct Connect Cable (DDN1463)
IMPORTANT NOTE: The APX 7500 Mobile dash-mount configuration is NOT supported with the MCC 5500. The O5
Control Head (G442) is optional and not required for connecting to the MCC 5500.
ORDER INSTRUCTIONS FOR APX 7500 MOBILE IN A TRAY (REMOTE MOUNT) to be used with the MCC 5500
Dispatch Console:
1. Main Model - Select any Mid Power APX 7500 Mobile
2. Operation Mode - Select either Operation Mode option, G241 or G806
3. System Enhancement Software - Select the corresponding software option to match your system.
4. Control Head Hardware - Select G88 - APX NO O5 CH NEEDED.
Note: G442 - APX O5 CONTROL HEAD can be ordered for visual use of the control head but is not required for
connecting to a MCC 5500.
5. Control Head Software - Select G444 - CONTROL HEAD SOFTWARE
6. Mounting - Select G67 - REMOTE MOUNT MID POWER
Note: The remote mount mobile is the only configuration for use with the MCC 5500.
7. RF Antenna - Select appropriate antenna option.
Note: G89 - NO RF ANTENNA NEEDED should be ordered if G88 selected in Step 4
8. Microphone - Select appropriate microphone option.
Note: G90 - NO MICROPHONE NEEDED should be ordered if G88 selected in Step 4
9. Speakers - Select appropriate speaker option.
Note: G142 - NO SPEAKER NEEDED should be ordered if G88 selected in Step 4
10. Order power supply for mobile - HPN4007C
Note: The power supply is not included with the mobile, this part must be ordered separately.
11. Order cable to connect radio to control head - HKN6170B
Note: This cable should be ordered only if G442 is selected in Step 4
Pa
g
e 7 of 16Dispatch Solutions \ MCC 5500 Dispatch Console
2/17/2015mk:
@
MSITStore:C:\Users\case02\Documents\ECAT
_