Installation Instruction Manual

4 INSTALLATION INSTRUCTIONS
M S D W W W . M S D P E R F O R M A N C E . C O M ( 9 1 5 ) 8 5 7 - 5 2 0 0 F A X ( 9 1 5 ) 8 5 7 - 3 3 4 4
Figure 6 Changing the Advance Stop Bushing.
SELECTING THE ADVANCE STOP
BUSHING
Three different advance stop bushings are supplied 
in the distributor kit. The distributor comes with a 
Blue (21°) bushing already installed. If a different 
amount of centrifugal advance is desired, follow the 
next procedure  to change the bushings.  The chart 
in Figure 5 gives the size and approximate degrees 
for the corresponding bushings.
CHANGING THE ADVANCE STOP
BUSHINGS
1. Remove the distributor cap and rotor.
2. Remove the locknut and washer on the bottom of 
the advance assembly (Figure 6).
3. Remove  the  bushing  and  install  the  new  one. 
Install the washer and locknut.
LOCKING OUT THE CENTRIFUGAL
ADVANCE
1.  Remove the advance components including the 
springs, weights and the advance stop bushing 
from the advance assembly.
2.  Remove theroll-pin fromthe shaft collar and slide 
the shaft two inches out of the housing.
3.  Rotate the shaft 180° and insert the advance stop 
bushing pin into the small hole on the advance 
plate (Figure 7).
4.  Install the locknutand washerto the advance stop 
bushing pin. This locks the advance in place.
5.  Install the shaft collar and roll-pin.
Note:If you want to lock out the vacuum advance of 
the Early Hemi Distributors, see page 6.
Figure 6  Locking Out the Centrifugal Advance.
Figure 7 Locking Out  the Advance.
Figure 5 Advance Stop Bushing Chart.
BUSHING SIZE APPROXIMATE
CRANKSHAFT
DEGREES
Red-Smallest  28
Silver  25
Blue  21
Black-Largest  18