Owners manual

INSTALLATION INSTRUCTIONS
7
MSD •  WWW.MSDPERFORMANCE.COM •  (915)  855-7123  •  FAX  (915)  857-3344
MODIFIED DUST COVER
1. The cap needs to be removed to connect the
MSD so disconnect the wiring connectors
from the distributor cap and lift it off the
distributor.
2. Remove the screws holding the dust cover in
position and lift the cover off.
3. Remove the four screws retaining the coil and
remove the coil and its wiring.
4. Inspect the rotor bushing for wear and replace
if necessary. Make sure the rubber bushing
remains in place and install the Modified Dust
Cover using the original hardware. Note that
the brass terminal must make contact with the
rotor bushing (Figure 4).
Figure 4 Installing the Modified Dust Cover.
LOW RESISTANCE
ROTOR BUSHING
MOUNTING THE BLASTER SS
1. Find a suitable mounting location for the coil.
It can be mounted in any position as long as
it is away from direct engine heat sources.
2. Use the coil as a template and mark the
mounting holes using a punch.
3. Using a 3/16” drill bit, drill the three holes to
mount the coil.
4. Install the vibration mounts and mount the
coil.
5. Install the Faston connectors to the coil
terminals. Connect the coil wires from the MSD
or stock ignition and the secondary coil wire.
Figure 5 Mounting Template.
CAUTION: Due to some printer set-
tings, it is recommended to
compare the document to
the actual part dimensions
before drilling holes! If the
printed document does
not match the actual part
dimensions, correct the
printer scaling settings and
print again.