Example: If the Time Switch function is used with an electric shifter to shift the transmission into 2nd
gear or High gear 0.70 seconds into the run with a duration of .030, figure 4 illustrates how the function
works in relation to time gure 4. For most shifter applications 0.25-0.30 seconds is adequate time
for the transmission to shift. Setting the duration with a lower time could cause inconsistent shifting
issues. Setting the value higher could cause issues with wasted CO2 (Air shifter) or a stuck plunger
(electric shifter). In most cases the shifter gate will prevent the shifter from advancing further without
the shifter plunger returning to the static position (Figure 4).
Note: Both the RPM and TIME Switch settings can be enabled at the same time. If both are enabled
at the same time, both RPM ON and Activation Point settings must be met before the output
wire will activate to ground. Be aware of the settings when both the timer and RPM settings are
enabled as the duration timer will start at the activation point regardless if the RPM condition
has been met or not. This can lead to erratic output wire results.