Owners manual

INSTALLATION INSTRUCTIONS 3
MSD •  WWW.MSDPERFORMANCE.COM •  (915)  857-5200  •  FAX  (915)  857-3344
If the RPM ON settings is programmed with a value higher than the RPM OFF setting, the RPM switch
functions as a hysteresis switch. The RPM switch will remain off until RPM increases above the ON
setting. The RPM Switch will remain active until the RPM decreases below the RPM OFF setting
(Figure 3).
Time Switch: There are two settings for this function Enabled/ Disabled. Default value is Disabled. To
activate the Time function change the value to Enabled
Activation Point: The setting can range from 0.00-30.00sec. This setting determines when the output
wire will activate after the launch wire is released from 12v. If this setting is set at 0.00 the output wire
will activate as soon as the launch wire is activated with 12v.
Duration: This setting can range from 0.00-30.00sec. This setting determines how long the output
wire will remain active after the Activation Point setting has been met. This setting will start counting
down after the launch wire has been released (in the event the Activation Point is set at 0.00).
Figure 3