up a window so the Launch limiter will not reactivate when using the clutch between shifts. This RPM
will be set lower than Launch RPM.
CONNECTING THE REV LIMITS
When you connect the Burnout and Launch, it is important to pay close attention to the wiring. The
Light Blue wire is responsible for the Burnout Rev Limit. The Dark Blue is responsible for turning on
the Launch Rev Limit. The Launch Rev Limit will override the Burn Rev Limit if both are activated.
LAUNCH RPM
The launch RPM is activated by applying 12 volts to the Launch Wire (Dark Blue Wire), this is normally
wired to a trans-brake button, brake line lock switch, or clutch switch on a manual shift transmission.
When 12 volts is removed from the Launch Wire the launch rpm will release and the Max RPM Value
will be in control of the engine RPM.
LAUNCH RETARD
Launch retard is primarily used in drag racing applications for consistancy and changing track
conditions.The launch retard can be activated multiple ways depending on the application. In order to
customize this feature to your application there are 3 adjustments that need to be made (Figure 11).
Delay: This is a time delay that starts counting once 12 volts is removed from the Launch Wire (Dark
Blue Wire). If this delay is set at 0 seconds, then the launch retard will become active as soon as 12
volts is applied to the Launch Wire. If you have anything other than 0 seconds (example: .10 or more),
then the launch retard will not become active until 12 volts is removed from the Launch Wire and the
Delay time is achieved. The setting ranges from 0-1.00 seconds.
REAL TIME
MONITOR
Figure 10 Pro-Data+ Screen and Program Windows.
RUN RETARD CURVE
BOOST/RETARD MAP
MENU
TREE
GAUGES
HELP
MENU