Specification Sheet
Specications & Order Information
Specication
Specications & Order Information
GAS TYPES
LEL
Gas
O
2
SO
2
NO
2
CO
H
2
S
H
2
S-LC
Range
0-100%
0-30%
0-20 ppm
0-50 ppm
0-1999 ppm
0-200 pm
0-100 ppm
Resolution
1%
0.1%
0.1 ppm
0.1 ppm
1 ppm
1 ppm
0.1 ppm
> 50 hours (adjustable)
> 500 event logs
4 years (+ optional 1-year extension)
Rechargeable Li-polymer battery
24-hour run-time
< 4 hour charge time
4.4 “ x 3.0” x 1.4”
11 cm x 7.6 cm x 3.5 cm
8 oz (228 g)
-40°F to +140°F
-40°C to +60°C
25-foot (7.5 m) drop protection
MIL-STD-810G drop protection
Certied IP68 rating
5% - 95% intermittent
15% - 90% non-condensing
TEMPERATURE
RANGE
POWER
DURABILITY
RELATIVE
HUMIDITY
PHYSICAL
DATALOGGING
WARRANTY
Description
ALTAIR 4XR Gas Detector Part Numbers
ATEX
10178573
10178569LEL, O
2
, CO, H
2
S
LEL, O
2
Need something dierent? Contact MSA for options.
Need to accommodate multiple cylinders? Contact MSA for options.
Don’t need a charger? Contact MSA for options.
, CO, H
2
S
Case Color
Charcoal
Phosphorescent
10106722EX Combustible
CO/H
2
S
SO
2
/H
2
S-LC
CO/NO
2
MSA GALAXY® GX2 Automated 4XR Test Stands for 1 Gas Cylinder
N. AmericaIntegrated 4XR Charger
Calibration Gas XCell Sensor Replacement Kits
1.45% CH
4
, 15% O
2
, 60 ppm CO, 20 ppm H
2
S
Europe UK Australia
Yes 10128630 10128639 10128669
No 10128642 10128651
10128659
10128661 10128671
34-liter cylinder
58-liter cylinder
CO/H
2
S-LC
CO-H
2
/H
2
S
USA/CAN
10178557
10178558
Kits with ALTAIR 4XR (LEL, O
2
, CO, H
2
S & Charcoal Case)
10178356
10178357
34-liter gas cylinder (1.45% CH
4
, 15% O
2
, 60 ppm CO, 20 ppm H
2
S)
Regulator (0.25 l/min)
ALTAIR Pump Probe
34-liter gas cylinder (1.45% CH
4
, 15% O
2
, 60 ppm CO, 20 ppm H
2
S)
Regulator (0.25 l/min)
USA/CAN
10048280
10045035
ALTAIR Pump Probe with charger
For USA/Canada
For ATEX/IEC
10152669
10052668
10106729O
2
10106725
10121213
10121214
10121215
10121217
Certications
North America
USA
Class I, Division 1, Groups A, B, C & D Class II,
Division 1, Groups E, F & G Class III, Division 1
Ambient temperature: -40°C to +60°C; T4
Canada CSA
CAN/CSA C22.2 No. 152 Combustible Gas Detection
Instruments C22.2 No. 152
Performance Ambient Temperature:
-20°C to +54°C; T4
C22.2 No. 157 Intrinsic Safety Ambient Temperature:
-40°C to +54°C; T4
Europe
Directive 2014/34/EU (ATEX): II 1G Ex ia da IIC T4 Ga,
-40°C to +60°C, IP68
CE 0080
Directive 2014/30/EU (EMC): EN50270 Type 2,
EN61000-6-3
IEC
IECEx
Ex ia da IIC T4 Ga, -40°C to +60°C, IP68
MSAsafety.com
Note: This Bulletin contains only a general description of the products shown.
While uses and performance capabilities are described, under no circumstances
shall the products be used by untrained or unqualied
individuals and not until the product instructions including
any warnings or cautions provided have been thoroughly read
and understood. Only they contain the complete and detailed
information concerning proper use and care of these products.
ID 0816-102-KIM / Jan 2017
© MSA 2017 Printed in U.S.A.
MSA – The Safety Company
1000 Cranberry Woods Drive
Cranberry Township, PA 16066 USA
Phone 724-776-8600
www.MSAsafety.com
U.S. Customer Service Center
Phone 1-800-MSA-2222
Fax 1-800-967-0398
MSA Canada
Phone 1-800-672-2222
Fax 1-800-967-0398
MSA Mexico
Phone 01 800 672 7222