Specification Sheet

Optional Heads-Up Display
Wireless Heads-Up-Display (HUD) System can be used with
Ultra Elite Facepiece; eliminates snag hazards, provides easy-
maintenance modularity. System is built with two primary
components, integrated transmitter and receiver. HUD
Transmitter provides user with remaining cylinder air volume
through four colored light logic LEDs:
Four green lights: 76 to 100% cylinder volume
Three green lights: 51 to 75% cylinder volume
Two ashing amber lights: 26 to 50% cylinder volume
Flashing red light: 0 to 25% cylinder volume
Optional Shoulder-mounted
Quick-Fill® System EBS Accessory
Connection oers SCBA cylinder rell from mobile compressor
or cascade system.
Allows translling between two SCBA wearers, providing
emergency breathing system (EBS).
Wearer’s air supply is extended over longer duration when
remote cascade system or other compressed air source is
located remotely, allowing transll and rell in IDLH
atmospheres.
Optional ICM® Tx Integrated
PASS/HUD Transmitter
ICM Tx Integrated PASS/HUD Transmitter features Personal Alert
Safety System (PASS) and HUD Transmitter combined within
single housing. Wireless system eliminates snag hazards and is
easily replaceable.
Optional Rapid Intervention Crew (RIC) System
Rapid Intervention Crew connection uses Quick-Fill System URC
(Universal Rescue Connection), enabling quick SCBA cylinder
relling (less than a minute) from mobile compressor or
cascade system.
Transll between two SCBA wearers to provide emergency
breathing system (EBS) while maintaining NIOSH approvals.
• RIC System extends wearers air supply over longer duration
when remote cascade system or other compressed air source
is located remotely, allowing wearers to transll and rell in
IDLH atmospheres.
Optional Emergency Egress
Rescue Belt II System
The Rescue Belt II System NIOSH-certied emergency egress
system is integral to SCBA waist belt, equipped complete
with 50-ft Kevlar line and rappelling hardware. Innovative
emergency egress device lets workers rappel to safety should
they become trapped in a building's upper level.
Options
Optional airline attachment congures AirHawk II Air Mask with second port for air-line connection from independent air source
(air compressor or cascade system), allowing workers an external air source as their primary air supply, conserving cylinder air for
emergency escape.
AirHawk II AirMask