User's Manual
(F) Main Circuit Board Diagram (with dip switches, adjustment pots, relays, antenna
adjustments identified)
(G) Dip Switch Settings Chart (Include drawing of dip switches)
Dip Switch Positions: 0= Left; 1= Right
Dip Default
Switch Function Setting
1* Detection Direction 0=Bi-directional 1=Uni-directional 1
2 Motion Sensitivity 0=Less Sensitive 1=More Sensitive 1
3 Threshold Safety 0=OFF 1=ON 1
4 Fail Safe State 0=Enabled 1=Disabled 0
5** M-T-P** 0=OFF 1=ON 1
6* Direction 0=Depart Only 1=Approach Only 1
*Dip Switch #6 is not used when Dip Switch #1 is set to “0”
*When Dip Switch #1 is set to “1” Be sure to select desired direction with Dip Switch #6
**MTP= Motion-To-Presence Feature: After initial detection the Activation Zone
converts from motion only detection to presence detection providing a larger Safety Zone
as shown (H)
(H) Motion-To-Presence (M-T-P) Diagram
(I) LED Glossary
Sensor Initialization Mode: With threshold safety ON (Dip Switch #6=1)
During the sensor initialization mode the activation (motion) zone of the detection
pattern is created and adjusted to desired size.
Warning w/symbol: Be sure to read this entire section before proceeding
1. Clear people and all temporary objects out of the detection pattern area.
2. Apply power to the sensor.
3. During the first 10 seconds after power is applied, the microStar is in its
initialization mode. The sensor will not detect motion and the LED flashes
GREEN. Press the LEARN button located on the PCB as shown (F) before the
LED stops flashing.
4. After pressing LEARN button the LED will confirm by flashing ORANGE. Wait
until LED turns solid GREEN before proceeding.
5. With LED solid GREEN, turn the Motion Range Pot to Maximum (factory
setting) as shown (F).
6. Walk test the pattern for motion detection as shown (J) by walking slowly towards
the door from several different angles. The LED will turn from solid Green to
solid RED when the sensor detects you.
(J) Activation Zone Walk Test