Service manual

Connect with indoor liquid pipe
Connect with outdoor liquid pipe
Bottom
Cover
Fetch out the power line and the connecting line.
Pay attention to fix firmly with wiring clamp.
1 2 3
80mm
MP3MP2 Electronic Expansion Valve Box figure:
MP3MP2 installation dimension:
MP3MP2installation procedure
1Installation of MP3MP2can be used for CEILING CONCEALED MODEL
APiping connection
aWhen connecting with indoor unitrefrigerant pipe and the connection wire must be
corresponding with the codeABC… on the device.
NOTE: When using two or more than two MP3 devices (need two or more than two
MP3 devices on connecting more than three indoor units), MUST mark definitely
Room code of connected indoor unit on the MP3 label, so as to air conditioner
maintain conveniently.
b When connecting indoor unit, firstly please weld MP3 with the corresponding
contribution pipe in the accessories table, then connect MP3 with corresponding indoor
connection pipe.
cMP3 can only be connected with liquid pipe of the unit, the gas pipe connection is the
same as the old ceiling concealed model.
200mm