Install Manual

Page 30
mrcool.com
Unit Installation
Electrical wiring of Single-phase unit: MDUO18024036 & MDUO18048060
Electrical Connection
Connecting the Power Cord & Thermostat Wire
Fig. 2.31-A
Power
Breaker
208/230V L1
1PH L2
60HZ G
L1
L2
Y
B
D
R
C
G
Indoor
Unit
Thermostat
LEGEND:
Y- Compressor control signal
B- is energized under the heating mode, means 4-way valve
control
D- defrosting signal
R- 24V AC power supply
C- 24V common
NOTE: When the outdoor unit defrosts, D will send an operation
signal to the electric heater to avoid cold winds. However, the
indoor fan should operate continuously, which is controlled by
the wire controller.
NOTE: As for the indoor units, which do not include D, there is no
need to connect the D terminals.
DO NOT bundle up the temperature thermostat wires and power wires, or lay them side by
side, otherwise errors will occur.
1. High and low voltage wires should be led through different rubber rings of the electric box cover.
2. High and low voltage wires should be secured separately.
3. Use screws to tighten the power cord and thermostat wire of the units on the terminal board. An
improper connection could create a fire hazard.
4. If the power cord and thermostat wires are not correctly connected, the air conditioner may suffer
damage.
5. Ground the units through connecting the ground wire and ensure it is secure.
6. The units should comply with applicable local and national rules and regulations on power
consumption.
7. When connecting the power cord, make sure the phase sequence of the power supply matches with
the corresponding terminals, otherwise the compressor will get reversed and operate abnormally.
WARNING