WARNING
The unit must be installed in a location strong enough to support the weight of the unit and
fixed securely, to avoid toppling.
Install the appliance in a location where there is an incline of less than 5°.
DO NOT install the unit in a location with direct sunlight to improve efficiency.
DO NOT install the unit where combustible or flammable gas leakage may occur.
1.
2.
2
Unit Installation
Select an installation location for the outdoor unit pursuant to the following conditions:
Noise and airflow produced by the outdoor unit will not disturb neighbors.
The location is away from animals and plants. If not, please add safety fences to protect the unit.
The area is well-ventilated with no nearby obstacles that could obstruct airflow.
The location is able to support the weight and withstand the operating vibration of the unit.
Installation is able to be performed safely.
The location area is free of combustible or corrosive gas, and oil smoke.
Unit is able to be shielded from strong winds. Strong wind could affect the outdoor fan and lead to
insufficient airflow volume, thus affecting the unit’s performance.
Unit is away from objects which can generate or amplify noise during operation.
Condensate can be safely drained from the unit.
1.
2.
3.
4.
5.
6.
7.
1. The Conventional Weld Line Set Installation
Instructions can be found on pages 15 - 23
OR
View complete install video by scanning this QR code
2.
No-Vac
®
Quick Connect
®
Line Set*
Installation
Instructions can be found on page 24
OR
View complete install video by scanning this QR code
The Universal
®
Series has 2 installation methods