507276-05CPage 50 of 57 mrcool.com
Blower Performance
MGM95SE045B3XA Performance (Less Filter)
External
Static
Pressure
in. w.c.
High Medium Low
cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts
1255 1150 185 895 105 95
1305 1225 250 1105 200 855 110 810 95
1290 360 1190 260 1080 205 825 120 780 105
1275 370 1150 270 215 785 125 720 110
1220 385 1120 280 1015 220 735 135 690 120
1215 390 1090 290 980 230 705 635 125
1190 395 1060 300 950 650 150 600 135
1015 300 900 250 620 155 555
1000 310 870 260 580 160 520
MGM95SE070B3XA Performance (Less Filter)
External
Static
Pressure
in. w.c.
High Medium Low
cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts
1380 315 1305 250 1190 200 965 105 920 100
1360 325 1270 255 1180 205 915 115 865 100
1310 335 1250 265 1130 215 880 120 815 110
1275 1205 275 1100 225 835 125 775 115
1250 355 1175 280 1065 230 795 135 730 125
1215 370 295 670 130
1200 380 1100 310 995 705 150
380 1070 310 960 255 670 160 585
1035 320 925 265 610 165 550 155
MGM95SE090C4XA Performance (Less Filter)
External
Static
Pressure
in. w.c.
High Medium Low
cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts
370 1505 250 1370 195 1285 160 1135 125
1695 390 265 1325 205 170 1090 135
1660 280 1290 220 1195 185
1615 1390 295 235 200 995 160
1590 1350 305 1200 1110 210 165
1560 1310 320 1155 260 1055 225 895 175
1525 1255 335 1105 270 1005 230 855 190
1220 1065 285 960 805 200
1170 355 1010 295 920 255 760 210