Specs

3
AHRI* CAPACITIES
Cooling Capacities and Efficiencies
UNIT SIZE NOMINAL TONS
STANDARD
CFM
NET COOLING CAPA-
CITY AT 95° F (35° C)
(Btuh)
EER† SEER**
024 2 800 24,000 11.50 14.50
030 2.5 1000 29,800 11.50 14.50
036 3 1200 36,000 11.50 14.50
042 3.5 1400 42,000 11.50 14.50
048 4 1600 46,500 11.50 14.00
060 5 1700 55,000 11.00 14.00
Heat Pump Heating Capacities and Efficiencies
UNIT SIZE
NET HEATING
CAPACITY AT 47° F
(8.3° C) (Btuh)
COP @ 47° F
(8.3° C)
NET HEATING
CAPACITY AT 17° F
(-8. C) (Btuh)
COP @ 17° F
(-8. C)
HSPF**
024 23,400 3.7 13,400 2.4 8.0
030 28,600 3.7 15,600 2.4 8.0
036 34,400 3.5 20,200 2.4 8.0
042 40,000 3.5 23,400 2.4 8.0
048 45,000 3.5 26,600 2.3 8.0
060 56,000 3.5 34,000 2.4 8.0
LEGEND
dB---Sound Levels (decibels)
db—Dry Bulb
SEER—Seasonal Energy Efficiency Ratio
wb—Wet Bulb
COP---Coefficient of Performance
* Air Conditioning Heating & Refrigeration Institute
At "A" conditions--80°F (26.7°C) indoor db/67°F (19.4°C) indoor wb & 95°F (35°C) outdoor db.
** Rated in accordance with U.S. Government DOE Department of Energy) test procedures and/or AHRI Standards 210/240.
Notes:
1. Ratings are net values, reflecting the effects of circulating fan heat.
Ratings are based on:
Cooling Standard: 80°F (26.7°C) db, 67°F wb (19.4°C) indoor entering---air temperature and 95°F db (35°C) outdoor entering---air temperature.
2. Before purchasing this appliance, read important energy cost and efficiency information available from your retailer.
Use of the AHRI Certified
TM Mark indicates a
manufacturer’s
participation in the
program For verification
of certification for individual
products, go to
www.ahridirectory.org.
A--Weighted Sound Power Level (dBA)
UNIT
SIZE
STANDARD RATING
(dBA)
TYPICAL OCTAVE BAND SPECTRUM (dBA without tone adjustment)
125 250 500 1000 2000 4000 8000
24 73 54.4 54.9 58.8 67.5 53.7 48.5 39.4
30 75 55.4 63.9 62.8 59.0 54.7 45.5 37.9
36 77 66.2 67.6 72.3 72.6 68.6 62.6 52.5
42 76 64.5 68.1 69.9 69.4 67.0 64.0 58.3
48 75.6 59.9 64.4 64.8 65.0 59.7 55.5 48.9
60 79 67.6 65.7 68.6 70.5 65.3 59.8 50.0
NOTE: Tested in accordance with AHRI Standard 270---1995 ( not listed in AHRI).
PH4Z