Specs
2
cooling operation down to 40F(4.4C). It’s high efficiency design
ensures high performance with most duct systems.
REFRIGERANT SYSTEM is designed to provide dependability.
Liquid refrigerant filter driers are used to promote clean,
unrestricted operation. Each unit leaves the factory with a full
refrigerant charge and is fully run tested. Refrigerant service
connections make checking operating pressure easier.
MODEL NUMBER NOMENCLATURE
PH4Z
TP
024
A
Typ e of Unit
P H 4 Z --- S i n g l e P a c k a g e d
Heat Pump System
Nominal Cooling Capacity
024 --- 2.0 To ns
030 --- 2.5 To ns
036 --- 3.0 To ns
042 --- 3.5 To ns
048 --- 4.0 To ns
060 --- 5.0 To ns
A
Heat Input Size (Btuh)
N/A
Electrical Supply
N --- 208/230--- 1---60
000
A
Series
Options
TP --- Base unit with tin plated indoor coil hairpins
Only used if ordering an option
N
Low NOx Indicator
A --- S t a n d a r d
N --- L o x N O x ( N / A )
Services
A
TABLE OF CONTENTS
PAGE
FEATURES/BENEFITS 1.........................................................................................
MODEL NUMBER NOMENCLATURE 2...........................................................................
AHRI CAPACITY RATINGS 3....................................................................................
PHYSICAL DATA 4.............................................................................................
ACCESSORIES 5...............................................................................................
DIMENSIONAL DRAWINGS 6...................................................................................
SELECTION PROCEDURE 9.....................................................................................
PERFORMANCE DATA 11.......................................................................................
TYPICAL WIRING SCHEMATICS 21..............................................................................
CONTROLS 23.................................................................................................
APPLICATION DATA 23.........................................................................................
GUIDE SPECIFICATIONS 24.....................................................................................
PH4Z