Specs

5
ACCESSORIES
ORDER
NUMBER
DESCRIPTION
Unit Size---Series
(Voltage)
1 8 --- A
(N)
2 4 --- A
(N)
3 0 --- A
(N)
3 6 --- B
(N)
3 6 --- B
(P)
3 6 --- B
(E)
4 2 --- A
(N)
4 8 --- A
(N)
4 8 --- A
(P)
4 8 --- A
(E)
6 0 --- A
(N)
6 0 --- A
(P)
6 0 --- A
(E)
HC32GE234 Ball Bearing Fan Motor X
HC34GE240 Ball Bearing Fan Motor X X X
HC38GE219 Ball Bearing Fan Motor X
HC40GE228 Ball Bearing Fan Motor X X
KAACH1601AAA Crankcase Heater Kit X X
KAACH1701AAA Crankcase Heater Kit X X X X
KAACS0201PTC PTC kit X X X X X X X
KAATD0101TDR Time Delay Relay X X X X X X X X X X X X X
KHAIR0201AAA Isolation Relay X X X X X X X X X X X X X
KHALS0401LLS Solenoid Valve Kit X X X X X X X X X X X X X
KHAOT0201SEC Outdoor Thermistor Kit X X X X X X X X X X X X X
KHAOT0301FST Outdoor Thermistor Kit X X X X X X X X X X X X X
KHASS0606MPK Snow Stand X X X X X X X X X X X X X
KSACY0101AAA Cycle Protector X X X X X X X X X X X X X
KSAFT0101AAA Freeze Thermostat X X X X X X X X X X X X X
KSAHS1701AAA Hard Start Kit X X X X X X X
KSALA0301410 Low Ambient Kit X X X X X X X X X X X X X
KSALA0601AAA Motormaster Kit X X X X X X X X X X
KSALA0701AAA Motormaster Kit X X X
KSASF0101AAA Support Feet X X X X X X X X X X X
KSASF0201AAA Support Feet X X
KSASH0601COP Sound Blanket X X X X X X X
KSASH2101COP Sound Blanket X X X X X X
KSATX0201PUR TXV Kit, Co ppe r Coi l X X X
KSATX0301PUR TXV Kit, Co ppe r Coi l X X X X
KSATX0501PUR TXV Kit, Co ppe r Coi l X X X X X X
KSBTX0201PUR TXV Kit, Aluminum Coil X X X
KSBTX0301PUR TXV Kit, Aluminum Coil X X X X
x = Accessory
ACCESSORY USAGE GUIDELINE
Accessory
REQUIRED FOR LOW ---AMBIENT
COOLING APPLICATIONS
(Below 55F / 12.8C)
REQUIRED FOR
LONG LINE APPLICATIONS*
REQUIRED FOR
SEA COAST APPLICATIONS
(Within 2 miles / 3.22 km)
Accumulator Standard Standard Standard
Ball Bearing F an Motor Ye s{ No} No}
Compressor Start Assist Capacitor and
Relay
Ye s* * Ye s* * No**
Crankcase Heater Ye s}
Ye s}
No}
Evaporator Freeze Thermostat Ye s No No
Hard Shutoff TXV Ye s Ye s No
Isolation Relay Ye s No No
Liquid Line Solenoid Valve No See Long---Line Application Guideline No
Motor Master Control or
Low Ambient Switch
Ye s No No
Support Feet Recommended No Recommended
* For tubing line sets between 80 and 200 ft. (24.38 and 60.96 m) and/or 20 ft. (6.09 m) vertical differential, refer to Residential Split---System Longline
Application Guideline.
{ Additional requirement for Low---Ambient Controller (full modulation feature) MotorMasterr Control.
} Standard for 3 phase units only
** Not required for 3---phase units.