Specs

7
ELECTRICAL DATA
UNIT SIZE --- SERIES V/PH
OPER VOLTS* COMPR FAN
MCA
MAX FUSE{ or
CKT BRK
AMPS
MAX MIN LRA RLA FLA
1 8 --- A
208/230/1---60 253 197
47.5 9.0 0.40 11.7 20
2 4 --- A 62.9 10.9 0.50 14.1 20
3 0 --- A 67.8 12.8 0.75 16.8 25
3 6 --- A 79.0 13.6 1.10 18.1 30
4 2 --- A 109.0 16.7 1.40 22.3 35
4 8 --- A 105.5 15.5 1.40 20.8 35
6 0 --- A 127.1 20.8 1.52 27.5 40
* Permissible limits of the voltage range at which the unit will operate satisfactorily
{ T i m e --- D e l a y f u s e .
FLA --- Fu l l L o a d A m p s
LRA --- L o c k e d R o t o r Am p s
MCA --- Minimum Circuit Amps
RLA ---RatedLoadAmps
NOTE: Control circuit is 24V on all units and requires external power source. Copper wire must be used from service disconnect to unit.
All motors/compressors contain internal overload protection.
Complies with 2010 requirements of ASHRAE Standards 90.1
A–WEIGHTED SOUND POWER (dBA)
UNIT SIZE --- SERIES
Standard
Rating (dBA)
TYPICAL OCTAVE BAND SPECTRUM (dBA without tone adjustment)
125 250 500 1000 2000 4000 8000
1 8 --- A 75 45.0 53.0 57.0 61.5 59.5 53.0 47.5
2 4 --- A 72 46.0 56.5 60.0 64.0 60.5 55.5 49.5
3 0 --- A 73 49.5 56.0 62.5 64.0 60.5 57.5 53.5
3 6 --- A 75 50.5 61.0 64.5 67.0 62.5 60.0 52.5
4 2 --- A 73 48.5 57.5 62.5 63.5 58.5 56.0 50.0
4 8 --- A 76 53.0 61.0 64.0 65.5 62.0 59.5 50.5
6 0 --- A 75 53.5 57.0 62.5 63.5 61.5 57.5 51.0
NOTE: Tested in compliance with AHRI 270–1995 (not listed with AHRI)
A–WEIGHTED SOUND POWER (dBA) WI TH SOUND SHI ELD
UNIT SIZE --- SERIES
Standard
Rating (dBA)
TYPICAL OCTAVE BAND SPECTRUM (dBA without tone adjustment)
125 250 500 1000 2000 4000 8000
1 8 --- A 75 45.0 53.0 57.5 61.5 60.5 54.5 48.5
2 4 --- A 73 46.5 59.0 60.5 63.5 60.5 55.0 47.5
3 0 --- A 72 49.0 56.5 61.5 62.5 60.0 57.0 52.0
3 6 --- A 75 51.0 62.0 64.5 65.5 62.0 59.5 51.5
4 2 --- A 72 49.5 58.0 62.0 63.0 58.0 55.0 47.0
4 8 --- A 73 54.5 61.0 63.5 62.5 60.0 56.5 47.5
6 0 --- A 73 53.5 59.0 63.0 62.5 59.5 56.0 48.0
NOTE: Tested in compliance with AHRI 270–1995 (not listed with AHRI)
METERING DEVICE
UNIT SIZE --- SERIES INDOOOR REQUIRED SUBCOOLING _F(_C)
1 8 --- A
TXV*
16 (8.89)
2 4 --- A 10 (5.56)
3 0 --- A 12 (6.67)
3 6 --- A 11 (6.11)
4 2 --- A 9 (5.00)
4 8 --- A 11 (6.11)
6 0 --- A 13 (7.22)
* TXV must be ordered separately when indoor coil is not equipped with a TXV. TXV must be hard–shutoff type.