Wired Control Install
3
2. INSTALLATION ACCESSORY
Precaution of installing the wire controller
1. This manual provides the installation method of wire controller. Please refer to the
wiring diagram of this installation manual to wire the wire controller with indoor unit.
2. The wire controller working in low voltage loop circuit. Forbid to directly contact the
cable of 220V commercial electricity or of 380V high voltage, and don’t wire this kind
of wire in the said loop; wiring clearance between congured tubes should at the
range of 11.8~19.7in or above.
3. The shielded wire of the wire controller must be grounded reliable.
4. Upon nishing the wire controller connection, do not use a tramegger to detect the
insulation.
5. The connective cable of wire controller should not be longer than 65.62ft.
For more info visit www.mrcool.com