Refrigerant Piping Connection
Before Test Run
Test Run Instructions
List of Checks to Perform PASS/FAIL
Outdoor (2): 
Indoor (2):
No electrical leakage
All electrical terminals 
properly covered
Indoor and outdoor units 
are solidly installed
All pipe connection points 
do not leak
Water drains properly 
from drain hose
All piping is properly 
insulated
function properly
function properly
Indoor unit louvers rotate 
properly
Indoor unit responds to 
remote control
You should perform the Test Run for at least 30 
minutes.
1.  Connect power to the unit.
2. Press the ON/OFF button on the remote 
controller to turn it on.
3. Press the MODE button to scroll through the 
following functions, one at a time:
  • COOL – Select lowest possible temperature
 • HEAT – Select highest possible temperature
4.   Let each function run for 5 minutes, and 
perform the following checks:
Only perform test run after you have 
completed the following steps:
• Electrical Safety Checks 
the electrical system is safe and operating 
properly
• Gas Leak Checks 
not leaking
pressure) valves are fully open
8
Test Run