Use and Care Manual

Table Of Contents
MRCOOL DC INVERTER COOLING ONLY CONDENSING UNIT
17
No.
Printing
Interface
No.
Printing
Interface
8
T_LAC
Low temperature cooling
temperature sensing
-
-
-
9
T_SENSOR2
2. Outdoor tube temperature
sensor interface
-
-
-
4. Outdoor ambient
temperature sensor interface
-
-
-
6. Discharge temperature
sensor interface
--
-
-
Drive Board:
Model: MDUCO18024036
No.
Printing
Interface
No.
Printing
Interface
1
L2-2
PFC induction wire (blue)
10
P-OUT
Reserved
2
AC-L
Live wire
11
L1-2
PFC induction wire (white)
3
L1-1
PFC induction wire (brown)
12
L2-1
PFC induction wire (yellow)
4
N
Neutral wire
13
G-OUT
Reserved
5
COMM1
Communication terminal, same with
COMM
14
U
Compressor U phase terminal
6
COMM
Communication terminal, same with
COMM1
15
V
Compressor V phase terminal
7
PWR
Drive power supply terminal
16
W
Compressor W phase terminal