16
7.1 Size Circuit And Install Disconnect Switch
Refer to the unit nameplate for minimum circuit ampacity, and maximum fuse or circuit breaker
(HACR per NEC). Install power wiring and properly sized disconnect switch.
Disconnect Switch
Main Fuse Box/Breaker Panel
Fig.16
NOTE: Units are approved for use only with copper conductors. Ground unit at disconnect
switch or to an earth ground.
7.2 Install Thermostat
Install room thermostat (ordered separately) on an inside wall approximately in the center of
the conditioned area and 5 feet (1.5m) from the oor. It should not be installed on an outside wall or
where it can be affected by sunlight or drafts.
Fig.17
NOTE: 24VAC, Class II circuit connections are made in the control panel.
7.3 Unit Low Voltage Connections
High voltage eld wiring
Low voltage (24v) eld wiring