mrcool 13seer r410 cond install manual 4web

Unitary Ducted Split AC & HP
9
3.5 Preparation for Next Step
After all connections have been brazed, disconnect manifold gauge set from service ports.
Apply water saturated cloths to both services valves to cool piping. Once piping is cool, remove all
water saturated cloths.Reinstall service cap and core.Refer to the unit installation instructions for
the next step in preparing the unit.
4. Check Piston
There is a piston located in outdoor condensing unit, please verify the piston size based on the
below table. When matching with air handler, please make sure replace this piston in air handler.
Table 3
OUTDOOR UNIT INDOOR UNIT PISTON KIT PART NO.
MAC13018 MAH13018 053
MAC13024 MAH13024 054
MAC13030 MAH13030 064
MAC13036 MAH13036 067
MAC13042 MAH13042 071
MAC13048 MAH13048 079
MAC13060 MAH13060 084
MHP13018 MAH13018 055
MHP13024 MAH13024 057
MHP13030 MAH13030 068
MHP13036 MAH13036 067
MHP13042 MAH13042 073
MHP13048 MAH13048 082
MHP13060 MAH13060 091
Liquid line orifice housing
Distributor assembly
Fixed orifice
Teflon ring
Liquid line assembly
(includes strainer)
Liquid line
Brass nut
Vapor line
Fig.10