Dimensions Guide
80% GAS FURNACE                              MGM80S*A & MGD80S*A
Page 2
MODEL NUMBER GUIDE
Note: For vent length and clearances to combustibles, please reference installation instructions.
REV CODE
A = 2ND GENERATION
CFM
CABINET SIZE
A = 14.5
2 = 800, 3 = 1200, 4 = 1600, 5 = 2000
B = 17.5
C = 21
D = 24.5
BTU
COMPANY
M = MRCOOL
GAS
G = GAS FURNACE
AIRFLOW
M = MULTI-POSITION
D = DOWNFLOW
AFUE
ANNUAL FUEL UTILIZATION EFFICIENCY
STAGE
S = SINGLE STAGE / MULTI SPEED
MOTOR
C = PSC
E = ECM
M G M 80 S C 45 A 3 A
mrcool.com
PHYSICAL AND ELECTRICAL DATA
Model
Input 
(Btuh)
Output 
(Btuh)
AFUE  
(ICS)
Nom. 
Cooling  
Capacity
Gas 
Inlet 
(in.)
Volts/  
Hz/ 
Phase
Max. 
Time 
Delay  
Breaker  
or Fuse
Nominal  
F.L.A.
Trans. 
(V.A.)
Approx.  
Shipping  
Weight  
(lbs.)
UPFLOW / HORIZONTAL
MGM80SE045A3A 44,000 35,200 80.0% 1-1/2  — 3 1/2 120-60-1 15 6.8 40 111
MGM80SE070B3A 66,000 52,800 80.0% 1-1/2  — 3 1/2 120-60-1 15 6.8 40 127
MGM80SE090B4A 88,000 70,400 80.0% 2-1/2  — 4 1/2 120-60-1 15 8.4 40 142
MGM80SE090C5A 88,000 70,400 80.0% 3  — 5 1/2 120-60-1 15 10.9 40 152
MGM80SE110C5A 110,000 88,000 80.0% 4   — 5 1/2 120-60-1 15 10.9 40 160
MGM80SE135D5A 132,000 105,600 80.0% 4   — 5 1/2 120-60-1 15 10.9 40 178
DOWNFLOW
MGD80SE045A3A 44,000 35,200 80.0% 2  — 3 1/2 120-60-1 15 6.8 40 113
MGD80SE070B3A 66,000 52,800 80.0% 2  — 3 1/2 120-60-1 15 6.8 40 128
MGD80SE090B4A 88,000 70,400 80.0% 3  — 4 1/2 120-60-1 15 8.4 40 140
MGD80SE110C5A 110,000 88,000 80.0% 4   — 5 1/2 120-60-1 15 10.9 40 160