HEATING PERFORMANCE EXT. RATINGS
MODEL NO.
HEATER
MODEL
Unit Supply
Voltage Single
Phase
Heater
kW
Min. Circuit
Ampacity
1
Max. Fuse /
HACR Brkr.
1
Min. Circuit
Ampacity
2
Max. Fuse /
HACR Brkr.
2
Min. Circuit
Ampacity
Single Point
Max. Fuse /
HACR Brkr.
Single Point
MPH601M414A
MHK05P
240 5 33.6 35 - - 64 80
208 3.8 30.2 35 - - 60.6 80
MHK07P
240 7.5 46.7 50 - - 77.1 90
208 5.6 41.5 45 - - 71.9 80
MHK15P
240 15 59.7 60 26 30 116.1 125
208 11.3 52.7 60 22.6 25 105.7 110
MHK20P
240 20 59.7 60 52.1 60 142.1 150
208 15 52.7 60 45.1 50 128.2 150
Model
Outdoor Temp. DB/WB deg. F
0/0 17/15 35/33 47/43 62/56
Btuh KW Btuh KW Btuh KW Btuh KW Btuh KW
MPH241M414A
MPH301M414A
MPH361M414A
MPH481M414A
MPH601M414A
MPH421M414A
7000 1.55 12300 1.60 17900 1.68 22000 1.71 27800 1.75
9900 1.92 15900 2.00 22200 2.10 27300 2.16 33000 2.23
19000 2.10 23800 2.40 28900 2.72 32300 2.93 36600 3.2
13600 2.88 23500 3.03 33900 3.19 40900 3.29 49600 3.42
15300 3.18 26300 3.35 57900 3.56 45700 3.66 55400 3.82
20100 3.89 33700 4.10 48100 4.51 57000 4.78 67400 4.88
HEAT PUMP PACKAGED UNIT MPH*1M414A