Brochure
PERFORMANCE RATINGS
OPEN LOOP CLOSED LOOP
(GROUND WATER HEAT PUMP) (GROUND LOOP HEAT PUMP)
COOLING HEATING COOLING HEATING
Entering Water Temperature Entering Water Temperature Entering Brine Temperature Entering Brine Temperature
59F 50F Full Load: 77F / Part Load: 68F Full Load: 32F / Part Load: 41F
MODEL LOAD FLUID FLOW AIRFLOW AIRFLOW CAPACITY EER CAPACITY COP CAPACITY EER CAPACITY COP
(GPM) (COOLING CFM) (HEATING CFM) (BTU/HR) (BTU/HR) (BTU/HR) (BTU/HR)
2 Ton
Full 8.0 1000 950 29,000 27.4 25,700 5.4 27,000 20.7 19,900 4.2
Part 7.0 850 800 23,000 36.5 19,000 5.5 21,900 29.1 16,500 4.7
3 Ton
Full 9.0 1350 1300 43,000 27.2 38,000 5.3 39,000 20.6 29,000 4.4
Part 8.0 1150 1100 33,000 35.7 27,500 5.6 30,300 29.0 24,000 4.8
4 Ton
Full 12.0 1850 1750 56,000 26.0 50,000 4.9 50,000 19.2 39,400 4.0
Part 11.0 1550 1500 41,000 33.0 34,500 5.0 38,000 27.0 30,000 4.5
5 Ton
Full 15.0 2300 2200 72,500 24.0 64,500 4.9 66,500 17.5 50,500 4.0
Part 14.0 1950 1850 55,200 31.0 47,000 5.2 53,400 26.0 41,000 4.6
HEATING CAPACITIES BASED ON 68.0°F DB / 59.0°F WB ENTERING AIR TEMPERATURE
ALL RATINGS BASED ON 208V / 60Hz / 1ph COOLING CAPACITIES BASED ON 80.6°F DB / 66.2°F WB ENTERING AIR TEMPERATURE
A B
C
D
E
F
G
H
I
J
DIMENSIONAL DATA
MODEL CABINET RETURN GROUND LOOP
DESUPERHEATER CONDENSATE WEIGHT
A X B X C D X E FILTER SIZE F G H I J
2 Ton
DOWNFLOW
25.75 X 32.00 X 56.00
26 X 28
28 X 30
35.88 47.94 35.275 43.525 3.75
325* - 335** LBS
3 Ton
DOWNFLOW
25.75 X 32.00 X 56.00
26 X 28
28 X 30
35.88 51.25 35.275 43.525 3.75
350* - 360** LBS
4 Ton
DOWNFLOW
25.75 X 32.00 X 60.00
30 X 28
32 X 30
39.88 55.13 39.275 47.525 3.75
380* - 390** LBS
5 Ton
DOWNFLOW
25.75 X 32.00 X 64.00
34 X 28
36 X 30
43.88 60.50 43.275 51.525 3.75
415* - 425** LBS
GROUND LOOP CONNECTIONS:
1" FPT
/ DESUPERHEATER CONNECTIONS:
3/4" FPT
/ CONDENSATE CONNECTION:
3/4" FPT
* UNIT WEIGHT NO DHW
FILTER RACK WIDTH IS
3"
. ("A" DIMENSION DOES NOT INCLUDE FILTER RACK WIDTH)
** UNIT WEIGHT WITH DESUPERHEATER